Volvo All Engines (2004 Emissions) Fault Code: SID 232 FMI 3 Sensor Supply Voltage #1
Fault Condition: The Electronic Malfunction Lamp (EML) will turn on and code SID 232 will set when the reference voltage to the Electronic Fan Controller, Boost Pressure Sensor and Intake Air Temperature and Humidity Sensor is less than 4.5 volts or greater than 5.5 volts. If the voltage returns to 4.5 volts to 5.5 volts, the fault will become inactive.
Possible repairs:
Turn the ignition key OFF first.
1) If code SID 232 is NOT set, wiggle the harness and connectors to try to set the code. Visually inspect the EMS Module connectors for frayed wires and loose or corroded connections.
2) Disconnect EMS Module connector A. Disconnect the Electronic Fan Controller, Boost Pressure Sensor and Intake Air Temperature and Humidity Sensor harness connectors. Check for continuity between EMS Module harness connector A, pin 7 and a good ground. If continuity exists, locate and repair the short circuit to ground.
3) Disconnect EMS Module connector A. Turn the ignition key ON. Measure the voltage between EMS Module connector A pin 7 and a good ground. If voltage is present, locate and repair the short circuit to voltage in circuit.
4) Disconnect EMS Module connector A. Disconnect the Electronic Fan Controller, Boost Pressure Sensor and Intake Air Temperature and Humidity Sensor harness connectors. Check for continuity between EMS Module
harness connector A, pin 7 and a pin 1 of the Electronic Fan Controller, Boost Pressure Sensor and Intake Air Temperature and Humidity Sensor connectors. If there is NO continuity, locate and repair the open in the circuit.
5) Disconnect EMS Module connector A. Visually inspect both sides of EMS Module connector A. If a repairable short circuit or damaged pins are found, repair or replace the harness connector.
6) Connect EMS Module connector A. Connect the Electronic Fan Controller, Boost Pressure Sensor and Intake Air Temperature and Humidity Sensor harness connectors. Start the engine and recheck for codes. If code SID 232 is still active, replace the EMS Module and retest the system. If code SID 232 is not active, the diagnostic procedures have corrected the problem. Check all connectors to ensure proper connections.
-
JPRO 2022 v1 Commercial Vehicle Diagnostics V1 Software Download & Installation Service ( 1 PC )
JPRO $94.00Rated 0 out of 5
-
download Hitachi Construction Machinery MPDr Ver 3.7.0.0 [10.2020] Diagnostic Software
Hitachi $76.00Rated 0 out of 5 -
10 IN 1 FOR CAT SIS Caterpillar 2021 Full Service Dealer INCLUDING CAT 2019 C
CAT $110.00Rated 0 out of 5 -
JOHN DEERE SERVICE ADVISOR 5.3.225 DATABASE AG + CF ENGLISH 2023
John Deere $250.00Rated 0 out of 5 -
Wabco ToolBox plus 13.7 + ECAS CAN2 v3.00 Diagnostics Software
Trucks software $84.00Rated 0 out of 5 -
CAT Engine Reprogramming Tool for flash programming C1.8, C2.4, C3.8 & C3.3B + Guide
CAT $50.00Rated 0 out of 5
Related products
-
Allison 1000 & 2000 Gen 4 Fault Codes: P0123 Pedal Position Sensor Circuit High Voltage
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1096 J1850 (Class 2) IPC Controller State of Health Failure
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U0100 CAN Bus ECM Error
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0846 Transmission Pressure Switch Solenoid D Circuit Stuck Open
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0218 Transmission Fluid Over Temperature Condition
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P2773 Torque Control Request Ignored – ECM/TCM
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0876 Transmission Reverse Pressure Switch Circuit Stuck Open
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U0073 CAN Bus Reset Counter Overrun
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P1688 Unmanaged Engine Torque Delivered To TCM Signal
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0880 TCM Supply Voltage
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0871 Transmission Pressure Switch Solenoid E Circuit Stuck Open
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0875 Transmission Reverse Pressure Switch Circuit Malfunction
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0848 Transmission Pressure Switch Solenoid D Circuit High
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P1892 Throttle Position Sensor Pulse Width Modulation (PWM) Signal High Input
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U2105 CAN Bus ECM Error
1000 & 2000 Gen 4 $50.00Rated 0 out of 5
-
SERVICE MANUAL 3000 AND 4000 SERIES GEN 4 GENERATION – ALLISON
Allison$19.00Original price was: $19.00.$17.00Current price is: $17.00.Rated 0 out of 5