Cummins ISB CM850 (2003-06) Fault Code: 272 (Auto) PID: SID 126 SPN: 1347 FMI: 3 High Fuel Pressure Solenoid Valve Circuit – Voltage Above Normal or Shorted to High Source. Electronic fuel control actuator shorted high.
Cummins ISB CM850 (2003-06) Fault Code: 272 (Auto) PID: SID 126 SPN: 1347 FMI: 3 High Fuel Pressure Solenoid Valve Circuit – Voltage Above Normal or Shorted to High Source. Electronic fuel control actuator shorted high.
This fault becomes active when the ECM detects an open in the electronic fuel control actuator circuit. Causes of this fault code are a short circuit to a positive voltage or an open circuit in the electronic fuel control actuator circuit. If there is high harness resistance, Fault Code 2311 could have high inactive counts. If the fault code is intermittent, look for causes of an intermittent open circuit such as loose pins and bad connections.
Possible repairs:
1)Replace the high-pressure fuel pump.
2)Repair or replace the engine harness, connector, or pins, if possible.
3)Replace the ECM.
-
VOLVO PREMIUM TECH TOOL PTT 2.7.30 Developer + Devtool + INSTALATION VIDEO!
Trucks software $60.00Rated 0 out of 5 -
DOWNLOAD Paccar ESA Electronic Service Analyst 5.5.0 Diagnostic Software 2023
PACCAR $96.00Rated 0 out of 5
-
Eaton Service Ranger 4.9 Engineering 4.9 [05.2021] Engineering Level ( 1 PC )
Eaton $67.00Rated 0 out of 5 -
PF Diagnose 2.0.2.23 Diagnostics Software 2013 – Full Heavy & Medium Duty with OBDII Support – Online Installation Service
PF Diagnose $60.00Rated 0 out of 5 -
DAF Davie Runtime v5.6.1 Davie XDc ll [02.2019] + Expire Fix 302.00 Unlock ( Windows 7 )
DAF $70.00Rated 0 out of 5 -
John Deere & Hitachi Parts ADVISOR 2020 [08.2020] Offline DVD Spare Parts Catalog
John Deere $120.00Rated 0 out of 5
Related products
-
SERVICE MANUAL International Engines DT466 & DT530 (1995-1998)
INTERNATIONAL ENGINES $34.00Rated 0 out of 5 -
SERVICE MANUAL Eaton Fuller – Autoshift, Autoselect Service Manual (TRSM-0050)
EATON $25.00Rated 0 out of 5