DETECTION CONDITIONS:
The engine control unit (E-ECU) registers:
1. Relay for preheating coil not activated.
2. That the voltage is above 0.65xUbat. (EB7)
SYMPTOM:
1. Relay may be continuously activated.
2. High cooling fan speed for charge-air cooling due to high inlet temperature.
3. High current consumption.
4. Poor battery.
POSSIBLE CAUSES:
1. Signal line short-circuited to Ubat. (EB7)
2. Relay continuously activated.
-