Volvo Engine D12D AE E3 (Tier 3) Fault Code: PID100 FMI 5 Engine Oil Pressure
Volvo Engine D12D AE E3 (Tier 3) Fault Code: PID100 FMI 5 Engine Oil Pressure
DETECTION CONDITIONS:
The engine control unit (E-ECU) registers current too low. (EB11)
SYMPTOM:
1. Monitoring stops.
2. Information display unit shows minus sign for oil pressure.
POSSIBLE CAUSES:
1. Open circuit on feed cable/signal line.
2. Short circuit on signal line.
-