Volvo Engine D11L (Tier 4) Fault Code: P06E617 PID: PSID 113 FMI: 3 Sensor Power Supply “C” – Circuit Voltage Above Threshold
Volvo Engine D11L (Tier 4) Fault Code: P06E617 PID: PSID 113 FMI: 3 Sensor Power Supply “C” – Circuit Voltage Above Threshold
CONTROL UNIT:
Engine ECU
FAILURE EVENT:
Voltage higher than 5.5 V has been detected.
SYMPTOM:
1. None.
2. There are no component connected to the supply.
CONDITIONS:
None
INHIBITING THE DTC:
U300001 / MID128 PID158 FMI5 / EF2104-5
POSSIBLE CAUSES:
Damaged wire harness or connector.
-