Volvo All Engines (2013 Emissions) Fault Code: P203A86 PID: EMS Reductant Level Sensor “A”

Volvo All Engines (2013 Emissions) Fault Code: P203A86 PID: EMS Reductant Level Sensor “A”

Circuit description
Aftertreatment Diesel Exhaust Fluid (DEF) Tank, Level Sensor has an indicator lamp and gauge in the instrument cluster. A solid lamp comes on when there is approximately 16% DEF remaining in the tank. A flashing lamp indicates when there is approximately 4% DEF remaining in the tank. A 25% engine derate is possible if the DEF is not refilled above the red line on the gauge at the next engine start up.

Conditions for diagnostic trouble code (DTC)
Low fluid level in the tank (Approximately?16%)
Low signal voltage from sensor

Probable cause
1) Low fluid level in the tank
2) Wiring harness
3) Aftertreatment diesel exhaust fluid (DEF) tank, Level Sensor, Temperature Sensor