The NOx sensor measures the amount of NOx in the exhaust system. The NOx sensor is connected in the J1939-2 data link. This diagnostic trouble code (DTC) indicates a NOx monitoring failure. For example; NOx sensor short- or open circuit, NOx sensor removed, NOx sensor missing signal.
Conditions for diagnostic trouble code (DTC):
1) Abnormal sensor signal
Observable symptoms
1) None
Probable cause
1) Sensor not mounted in exhaust stream
2) Charge air system leakage
3) Exhaust system leakage
4) DEF dosing system
5) NOx sensor
6) EGR Cooler
7) EGR Valve
8) Variable Geometry Turbo
Detailed information
1) The component is not activated only when the ignition is in the ON position, or by starting the engine