Volvo All Engines (2004 Emissions) Fault Code: PID 172 FMI 5 Intake Air and Humidity Sensor
Fault Condition: The Electronic Malfunction Lamp (EML) will turn on and PID 172 will set when the Engine Management System (EMS) Module senses that the Intake Air Temperature Sensor signal voltage is less than 0.5 volts or greater than 4.9 volts for 1 second. If the Intake Air Temperature Sensor voltage returns to between 0.5 volts and 4.9 volts for more than 1 second, the fault will become inactive.
Possible repairs:
Turn the ignition key OFF first.
1) Disconnect the Intake Air Temperature and Humidity (IATH) Sensor connector. Measure the resistance between pins 3 and 4 of the Intake Air Temperature and Humidity (IATH) Sensor with the ambient air temperature between 32° and 104°F (0° and 40°C) If the measured resistance is NOT between 30029 and 5575 ohms, replace the sensor.
2) Disconnect the Intake Air Temperature and Humidity (IATH) Sensor connector. If continuity exists on any pin, replace the Intake Air Temperature and Humidity (IATH) Sensor.
3) Disconnect the Intake Air Temperature and Humidity (IATH) Sensor harness connector. Measure the resistance between pins 3 and 4 of the Intake Air Temperature and Humidity (IATH) Sensor with the ambient air temperature between 32° and 104°F (0° and 40°C). If the measured resistance is NOT between 30029 and 5575 ohms, replace the Intake Air Temperature and Humidity (IATH) Sensor.
4) Connect the Intake Air Temperature and Humidity (IATH) Sensor harness connector. Connect connectors to the Engine Management System (EMS) Module. Turn the ignition key ON. If PID 172 is still active, check the Engine
Management System (EMS) Module and connector A for dirt, loose or shorted pins, or any other repairable damage. If no problems are evident or are not repairable, replace the Engine Management System (EMS) Module
and retest the system. If PID 172 is NOT active, the diagnostic procedures have corrected the problem. Check all connectors to ensure proper connections.
5) Disconnect the Intake Air Temperature and Humidity (IATH) Sensor harness connector. Disconnect Engine Management System (EMS) Module harness connectors A and B. Check for continuity between Engine
Management System (EMS) Module harness connector A pin 43 and all other pins on Engine Management System (EMS) Module connectors A and B. If continuity exists, the signal line is shorted to one of the other Engine Management System (EMS) Module circuits. Locate and repair the short circuit to voltage, then replace the sensor. If there is NO continuity, the signal line is shorted to voltage somewhere else in the harness. Locate and repair the short circuit to voltage, then replace the sensor.
6) Connect the Intake Air Temperature and Humidity (IATH) Sensor harness connector. Connect connector A to the Engine Management System (EMS) Module. Turn the ignition key ON. If PID 172 is still active, check the Engine
Management System (EMS) Module and connectors A, and B for dirt, loose or shorted pins, or any other repairable damage. If no problems are evident or are not repairable, replace the Engine Management System (EMS) Module and retest the system. If PID 172 is NOT active, the diagnostic procedures have corrected the problem. Check all connectors to ensure proper connections.
-
Wabco ToolBox plus 13.7.0.1 + ECAS CAN2 v3.00 Diagnostics Software
Trucks software $84.00Rated 0 out of 5 -
VOLVO PREMIUM TECH TOOL PTT 2.7.116 + APCI 2021 + devtool ( ONLINE )
Trucks software $80.00Rated 0 out of 5
-
International Truck ISIS – Oncommand Service Information Q4.2020 [04.2020]
Navistar $85.00Rated 0 out of 5 -
DAF Davie Runtime v5.6.1 Davie XDc ll [02.2019] + Expire Fix 302.00 Unlock ( Windows 7 )
DAF $70.00Rated 0 out of 5 -
DETROIT DDDL 8.14 SP3 – Detroit Diesel Diagnostic Link 8.14 SP3 2021 ( 1PC )
Detroit $73.00Rated 0 out of 5 -
premium volvo tech tool update 2.8.150 diagnostic software 1pc
Trucks software $150.00Rated 0 out of 5 -
JPRO 2022 v1 Commercial Vehicle Diagnostics V1 Software Download & Installation Service ( 1 PC )
JPRO $94.00Rated 0 out of 5 -
download MANCATS II v14.01 2014 Diagnostic software MAN CATS ( virtual machine )
MAN $75.00Rated 0 out of 5
Related products
-
Allison 1000 & 2000 Gen 4 Fault Codes: U1000 Class 2 Loss of Serial Data Communication
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0876 Transmission Reverse Pressure Switch Circuit Stuck Open
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0122 Pedal Position Sensor Circuit Low Voltage
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1096 J1850 (Class 2) IPC Controller State of Health Failure
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U0100 CAN Bus ECM Error
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0847 Transmission Pressure Switch Solenoid D Circuit Stuck Closed
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P1892 Throttle Position Sensor Pulse Width Modulation (PWM) Signal High Input
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P2810 Solenoid G Electrical
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0846 Transmission Pressure Switch Solenoid D Circuit Stuck Open
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0871 Transmission Pressure Switch Solenoid E Circuit Stuck Open
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1300 J1850 (Class 2) Serial Data Communication Link Low
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P2773 Torque Control Request Ignored – ECM/TCM
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U0032 J1850 (Class 2) Serial Data Communication Link High
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U0031 J1850 (Class 2) Serial Data Communication Link Low
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1301 J1850 (Class 2) Serial Data Communication Link Low
1000 & 2000 Gen 4 $50.00Rated 0 out of 5
-
SERVICE MANUAL DETROIT DIESEL DD15 , DD13 Service Workshop Repair Manual
DETROIT $25.00Rated 0 out of 5 -
SERVICE MANUAL 3000 AND 4000 SERIES GEN 4 GENERATION – ALLISON
Allison$19.00Original price was: $19.00.$17.00Current price is: $17.00.Rated 0 out of 5