PACCAR PX-9 CM2350 (2013-17) Fault Code1974 PID:101 SPN:101 FMI:15 Crankcase Pressure – Data Valid But Above Normal Operating Range – Moderately Severe Level
Reason:
Crankcase Pressure – Data Valid But Above Normal Operating Range – Moderately Severe Level. The crankcase breather filter requires maintenance.
Effect:
None on performance.
Circuit Description:
The crankcase pressure sensor is used to monitor the pressure inside the crankcase. The engine control module (ECM) supplies the crankcase pressure sensor a 5 volt reference voltage. When the crankcase pressure is low, the sensor signal voltage is low. When the crankcase pressure is high, the sensor signal voltage is near the 5 volt reference voltage. The ECM monitors the crankcase pressure signal circuit voltage to calculate the pressure of the air within the crankcase.
Component Location:
The crankcase pressure sensor is located near the crankcase ventilation filter.
Conditions for Running the Diagnostics:
This diagnostic runs continuously when the engine is operating at idle.
Conditions for Setting the Fault Codes:
The Engine Control Module (ECM) detected the crankcase pressure reading was higher than a threshold for 60 cumulative minutes at idle.
Action Taken When the Fault Code is Active:
The ECM illuminates the white MAINTENANCE lamp or flashes the amber CHECK ENGINE lamp, indicating a maintenance condition, immediately after the diagnostic runs and fails.
Conditions for Clearing the Fault Code:
1) To validate the repair, start the engine and let it idle for 1 minute.
2) The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults.
Shop Talk:
If this fault code is active, the crankcase breather element may need to be replaced.
Possible Causes:
1) Inactive fault codes
2) Bad crankcase ventillation system
3) Faulty ECM
-
DOWNLOAD Paccar ESA Electronic Service Analyst 5.5.0 Diagnostic Software 2023
PACCAR $96.00Rated 0 out of 5
Related products
-
Allison 1000 & 2000 Gen 4 Fault Codes: P0123 Pedal Position Sensor Circuit High Voltage
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1064 J1850 (Class 2) TBC Controller State of Health Failure
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1041 J1850 (Class 2) ABS Controller State of Health Failure
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U2105 CAN Bus ECM Error
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U2104 CAN Bus Reset Counter Overrun
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1016 Class 2 J1850 (Class 2) Powertrain Controller State of Health Failure
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0872 Transmission Pressure Switch Solenoid E Circuit Stuck Closed
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0870 Transmission Pressure Switch Solenoid E Circuit
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P1891 Engine Throttle Position Sensor Pulse Width Modulation (PWM) Signal Low Input
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P2771 Four-Wheel Drive Switch Circuit
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P2810 Solenoid G Electrical
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P1688 Unmanaged Engine Torque Delivered To TCM Signal
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0876 Transmission Reverse Pressure Switch Circuit Stuck Open
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U0100 CAN Bus ECM Error
1000 & 2000 Gen 4 $50.00Rated 0 out of 5