PACCAR MX (2004 Emissions) Fault Code: U1856 DOC DPF Temperature Sensors ECU Software Verification – Incorrect
PACCAR MX (2004 Emissions) Fault Code: U1856 DOC DPF Temperature Sensors ECU Software Verification – Incorrect
SET CONDITIONS:
The PCI ECU detects that no or an incorrect calibration verification number (CVN) is received from the DOC/DPF temperature sensors ECU.
DIAGNOSTIC CONDITION:
This diagnostic runs once when the ignition is keyed on.
CORRESPONDING OBD READINESS MONITOR:
None
RESET CONDITION:
This DTC changes to inactive next time the ignition is keyed on and the fault is no longer detected.
REPAIR VERIFICATION:
1. Clear all DTCs.
2. Test drive or operate the vehicle to meet the diagnostic conditions and set conditions.
3. Did the DTC come back? (Can be pending, inactive or active)
– No, repair successful
– Yes, repair unsuccessful
POSSIBLE CAUSES:
1. No or intermittent CAN communication with the DOC/DPF temperature sensors ECU
2. Incorrect type of DOC/DPF temperature sensors ECU installed
3. Faulty DOC/DPF temperature sensors ECU
ADDITIONAL INFORMATION:
When the ignition is keyed on, the PCI ECU (D420) queries the DOC/DPF temperature sensors ECU (D418) for a calibration verification number (CVN).
CVN is the calibration verification number and is the result of a check performed on the software values stored in emission-related ECUs (OBD legislation).
-
PACCAR Electronic Service Analyst 5.4.3.0 SW files 27.03.2021 software trucks
PACCAR $60.00Rated 0 out of 5 -
PF Diagnose 2.0.2.23 Diagnostics Software 2013 – Full Heavy & Medium Duty with OBDII Support – Online Installation Service
PF Diagnose $60.00Rated 0 out of 5
Related products
-
SERVICE MANUAL DETROIT DIESEL DDEC VI – Application And Installation Manual
DETROIT $20.00Rated 0 out of 5