PACCAR MX (2004 Emissions) Fault Code: U1802 VTG Turbocharger Actuator Power Supply – Data Valid but Too High
PACCAR MX (2004 Emissions) Fault Code: U1802 VTG Turbocharger Actuator Power Supply – Data Valid but Too High
SET CONDITIONS:
The VTG turbo charger actuator (L037) detects that the actuator power supply is above 17 volts for more than 40 seconds.
DIAGNOSTIC CONDITION:
This diagnostic runs continuously when the ignition is on.
CORRESPONDING OBD READINESS MONITOR:
None
RESET CONDITION:
This DTC changes to inactive after the ignition is keyed off and keyed on again and the fault is no longer detected.
REPAIR VERIFICATION:
1. Clear all DTCs.
2. Test drive or operate the vehicle to meet the diagnostic conditions and set conditions.
3. Did the DTC come back?
– No, repair successful
– Yes, repair unsuccessful
POSSIBLE CAUSES:
1. VTG turbocharger actuator power supply, check:
– Whether more ECUs on the vehicle detect incorrect power supply
– Battery voltage (faulty alternator)
– VTG turbocharger actuator power supply
2. Faulty VTG turbo charger actuator if the DTC remains active after the above is performed/checked
ADDITIONAL INFORMATION:
The power supply of the actuator is continuously monitored.
-
Volvo Intermediate Storage File Encryptor/Decryptor (Editor) VISFED 0.3.2
Trucks software $35.00Rated 0 out of 5
-
download MANCATS II v14.01 2014 Diagnostic software MAN CATS ( virtual machine )
MAN $75.00Rated 0 out of 5 -
Bobcat Service Library [03.2019] Service, Operator, Maintenance, Bulletines, etc full update
Bobcat $110.00Rated 0 out of 5 -
Hino Diagnostic eXplorer 2 – Hino DX2 1.1.19.1 with keygen unlocked ( Hino trucks )
Hino $50.00Rated 0 out of 5