PACCAR MX (2004 Emissions) Fault Code: U1161 CAN – Message (A1SCRAI2) Time-Out from Aftertreatment System
PACCAR MX (2004 Emissions) Fault Code: U1161 CAN – Message (A1SCRAI2) Time-Out from Aftertreatment System
SET CONDITIONS:
This DTC is set when the repetition rate of the received CAN message is lower than expected or when the message is not received at all.
DIAGNOSTIC CONDITION:
The diagnostic runs continuously when the ignition is keyed on or when the engine is running.
CORRESPONDING OBD READINESS MONITOR:
None
RESET CONDITION:
The DTC changes to inactive after the diagnostic runs and passes.
REPAIR VERIFICATION:
1. Clear all DTCs.
2. Test drive or operate the vehicle to meet the diagnostic conditions and set conditions.
3. Did the DTC come back?
– No, repair successful
– Yes, repair unsuccessful
POSSIBLE CAUSES:
1. Wiring issues (interruption or contact resistance)
2. Defective components
3. Incorrect software configuration
-
CAT CDVR PC Software – Caterpillar Digital Voltage Regulator (CDVR) WINDOWS 10
CAT $45.00Rated 0 out of 5 -
DOWNLOAD NISSAN UD DIESEL PC-CONSULT DIAGNOSTIC 1.1.13 & PC-REPROMASTER 1.2.0
NISSAN UD $100.00Rated 0 out of 5 -
PF Diagnose 2.0.2.23 Diagnostics Software 2013 – Full Heavy & Medium Duty with OBDII Support – Online Installation Service
PF Diagnose $60.00Rated 0 out of 5
-
DAF Davie Runtime v5.6.1 Davie XDc ll [02.2019] + Expire Fix 302.00 Unlock ( Windows 7 )
DAF $70.00Rated 0 out of 5 -
Eaton Service Ranger 4.9 Engineering 4.9 [05.2021] Engineering Level ( 1 PC )
Eaton $67.00Rated 0 out of 5 -
International Truck ISIS – Oncommand Service Information Q4.2020 [04.2020]
Navistar $85.00Rated 0 out of 5
Related products
-
SERVICE MANUAL DETROIT DIESEL DD15 , DD13 Service Workshop Repair Manual
DETROIT $25.00Rated 0 out of 5 -
SERVICE MANUAL International Engines DT466E & DT530E (1999 & Older)
INTERNATIONAL ENGINES $31.00Rated 0 out of 5