PACCAR MX (2004 Emissions) Fault Code: P3003 PCI ECU Power Supply – Data Valid but Too Low
PACCAR MX (2004 Emissions) Fault Code: P3003 PCI ECU Power Supply – Data Valid but Too Low
SET CONDITIONS:
The PCI ECU (D420) detects that the power supply has dropped to below 10 V.
DIAGNOSTIC CONDITION:
This diagnostic runs continuously after starting and running the engine.
CORRESPONDING OBD READINESS MONITOR:
None
RESET CONDITION:
This DTC changes to inactive when the fault is no longer detected.
REPAIR VERIFICATION:
1. Clear all DTCs.
2. Test drive or operate the vehicle to meet the diagnostic conditions and set conditions.
3. Did the DTC come back?
– No, repair successful
– Yes, repair unsuccessful
POSSIBLE CAUSES:
1. Alternator malfunctioning
2. PCI ECU power supply, check:
– Whether more ECUs on the vehicle detect incorrect power supply
– Battery voltage
– PCI ECU power supply
ADDITIONAL INFORMATION:
For this diagnostic, the PCI ECU monitors its power supply only during engine operation to detect a running voltage drain-down. It does not detect a cranking voltage drain-down.
Related
-
DPF EGR SCR BAC ERG Delete & Flash CAAT Cummings Detroit Dodge Mack Volvo Collection of DELETE files
CAT $200.00Rated 0 out of 5
-
DETROIT DDDL 8.14 SP3 – Detroit Diesel Diagnostic Link 8.14 SP3 2021 ( 1PC )
Detroit $73.00Rated 0 out of 5 -
John Deere & Hitachi Parts ADVISOR 2020 [08.2020] Offline DVD Spare Parts Catalog
John Deere $120.00Rated 0 out of 5 -
Navistar international OnCommand service information 2018 software trucks
Navistar $50.00Rated 0 out of 5 -
DAF Davie Runtime v5.6.1 Davie XDc ll [02.2019] + Expire Fix 302.00 Unlock ( Windows 7 )
DAF $70.00Rated 0 out of 5
Related products
-
SERVICE MANUAL Eaton Fuller – Autoshift, Autoselect Service Manual (TRSM-0050)
EATON $25.00Rated 0 out of 5 -
SERVICE MANUAL International Engines MaxxForce 7 (2010 & Newer)
INTERNATIONAL ENGINES $34.00Rated 0 out of 5