PACCAR MX (2004 Emissions) Fault Code: P2541 Fuel Pressure – Voltage Too Low or Short Circuit to Ground on ECU (D420) Pin (A50)
PACCAR MX (2004 Emissions) Fault Code: P2541 Fuel Pressure – Voltage Too Low or Short Circuit to Ground on ECU (D420) Pin (A50)
SET CONDITIONS:
This DTC is set when the ECU detects a lower voltage than expected on the signal or control circuit of the ECU.
DIAGNOSTIC CONDITION:
The diagnostic runs continuously when the ignition is keyed on.
CORRESPONDING OBD READINESS MONITOR:
None
RESET CONDITION:
The DTC changes to inactive after the diagnostic runs and passes.
REPAIR VERIFICATION:
1. Clear all DTCs.
2. Test drive or operate the vehicle to meet the diagnostic conditions and set conditions.
3. Did the DTC come back?
– No, repair successful
– yes, repair unsuccessful
POSSIBLE CAUSES:
1. The sensor or actuator signal wiring is interrupted.
2. The sensor or actuator signal wiring has a short circuit to ground.
3. A malfunction in the power supply of the sensor or actuator
4. A malfunction of the sensor or actuator
ADDITIONAL INFORMATION:
Multiple sensor related voltage-too-low DTCs can indicate a malfunction within a 5-V sensor power supply circuit of the PCI ECU.
-
Bobcat Service Library [03.2019] Service, Operator, Maintenance, Bulletines, etc full update
Bobcat $110.00Rated 0 out of 5 -
Scania SDP3 2.48.6 Diagnosis & Programming for VCI 3 VCI3 without Dongle
Scania $30.00Rated 0 out of 5 -
DOWNLOAD Paccar ESA Electronic Service Analyst 5.5.0 Diagnostic Software 2023
PACCAR $96.00Rated 0 out of 5 -
VOLVO PREMIUM TECH TOOL PTT 2.7.116 + APCI 2021 + devtool ( ONLINE )
Trucks software $80.00Rated 0 out of 5 -
ddct Detroit diesel calibration tool (DDCT) v4.5 English Include Calibrations & Metafiles
Detroit $30.00Rated 0 out of 5 -
Hino Diagnostic eXplorer 2 – Hino DX2 v1.1.21.4 with keygen unlocked ( Hino trucks )
Hino $60.00Rated 0 out of 5