PACCAR MX (2004 Emissions) Fault Code: P2151 Common Rail Pump Unit 2 – Voltage Too High or Short Circuit to Supply on ECU (D420) Pin (A27)
PACCAR MX (2004 Emissions) Fault Code: P2151 Common Rail Pump Unit 2 – Voltage Too High or Short Circuit to Supply on ECU (D420) Pin (A27)
SET CONDITIONS:
This DTC is set when the ECU detects a higher voltage than expected on the signal or control circuit of the ECU.
DIAGNOSTIC CONDITION:
The diagnostic runs continuously when the ignition is keyed on.
CORRESPONDING OBD READINESS MONITOR:
None
RESET CONDITION:
The DTC changes to inactive after the diagnostic runs and passes.
REPAIR VERIFICATION:
1. Clear all DTCs.
2. Test drive or operate the vehicle to meet the diagnostic conditions and set conditions.
3. Did the DTC come back?
– No, repair successful
– Yes, repair unsuccessful
POSSIBLE CAUSES:
1. The sensor or actuator signal wiring has a short circuit to supply.
2. A malfunction of the sensor or actuator
ADDITIONAL INFORMATION:
When this DTC is active:
1. The engine torque is reduced.
2. The engine runs in protection mode.
3. The maximum rail pressure is limited to 1300 bar.
-
download Hitachi Construction Machinery MPDr Ver 3.7.0.0 [10.2020] Diagnostic Software
Hitachi $76.00Rated 0 out of 5
-
CAT CDVR PC Software – Caterpillar Digital Voltage Regulator (CDVR) WINDOWS 10
CAT $45.00Rated 0 out of 5 -
CLAAS WebTIC Offline [11.2021] Service Information – ENGLISH Language
CLAAS $100.00Rated 0 out of 5 -
download MANCATS II v14.01 2014 Diagnostic software MAN CATS ( virtual machine )
MAN $75.00Rated 0 out of 5 -
John Deere & Hitachi Parts ADVISOR 2020 [08.2020] Offline DVD Spare Parts Catalog
John Deere $120.00Rated 0 out of 5
Related products
-
SERVICE MANUAL Eaton Fuller – Autoshift, Autoselect Service Manual (TRSM-0050)
EATON $25.00Rated 0 out of 5 -
SERVICE MANUAL DETROIT DIESEL DDEC III-IV Single ECM Troubleshooting Guide
DETROIT $48.00Rated 0 out of 5