PACCAR MX (2004 Emissions) Fault Code: P170F NOx Concentration Before Catalyst – Data Valid but Too High During Overrun
PACCAR MX (2004 Emissions) Fault Code: P170F NOx Concentration Before Catalyst – Data Valid but Too High During Overrun
SET CONDITIONS:
The PCI ECU (D420) detects that the measured engine NOx emissions are too high for a fuel injection cutout situation for more than 21 seconds.
DIAGNOSTIC CONDITION:
This diagnostic runs:
1. During coasting (no fuel injection) and
2. When the coolant temperature is above 50°C [122°F] and
3. The NOx sensor before catalyst (F844) is in the operating mode
CORRESPONDING OBD READINESS MONITOR:
Exhaust gas sensors monitor
RESET CONDITION:
This DTC changes to inactive when the fault is no longer detected.
IMPORTANT:
1. For Eaton Ultrashift transmissions, idle drop can only go to 1000 rpm.
2. For Alison Autoshift transmissions, it is not possible to conduct this test.
REPAIR VERIFICATION:
1. Clear all DTCs.
2. Test drive or operate the vehicle to meet the following conditions:
– Corresponding readiness monitor displays ‘Ready’
– Diagnostic conditions are met
– Set conditions are met
3. Did the DTC come back? (Can be pending, inactive or active)
– No, repair successful
– Yes, repair unsuccessful
POSSIBLE CAUSES:
NOx sensor before catalyst deviation
ADDITIONAL INFORMATION:
1. The measured engine NOx emissions are compared with the expected engine NOx emissions while coasting (fuel injection cutout).
2. The engine NOx emissions are measured by the NOx sensor before catalyst (F844).
Related
-
PF Diagnose 2.0.2.23 Diagnostics Software 2013 – Full Heavy & Medium Duty with OBDII Support – Online Installation Service
PF Diagnose $60.00Rated 0 out of 5
-
DAF Davie Runtime v5.6.1 Davie XDc ll [02.2019] + Expire Fix 302.00 Unlock ( Windows 7 )
DAF $70.00Rated 0 out of 5 -
Volvo PROSIS Offline 2019 Parts Catalog Installation Service
Trucks software $45.00Rated 0 out of 5 -
Detroit Diesel Diagnostic Link DDDL 8.0 PRO PROFESSIONAL Software trucks
Detroit $25.00Rated 0 out of 5 -
Scania SDP3 2.48.6 Diagnosis & Programming for VCI 3 VCI3 without Dongle
Scania $30.00Rated 0 out of 5 -
CAT CDVR PC Software – Caterpillar Digital Voltage Regulator (CDVR) WINDOWS 10
CAT $45.00Rated 0 out of 5
Related products
-
SERVICE MANUAL Carrie Supra 422, 522,622, 722, 822,922, 644,744,844, 944 & Supra Multi-Temp
CARRIE $20.00Rated 0 out of 5