Eaton Fuller Advantage (2017) Fault Code: 72 PID: SID 59 SPN: FMI: 7 Failed to Select Rail: Mechanical System Not Responding
Overview:
The Fuller Advantage transmission uses the X-Y Shifter to engage and disengage a gear based on the driver’s selected mode of operation. Rail selection is achieved by activating the X-Y Shifter Rail Motor, which controls the lateral movement of the X-Y Shift Finger within the Shift Bar Housing. Certain shifts require the transmission to engage a different rail on the Shift Bar Housing. These rail shifts require the X-Y Shifter to move to Neutral prior to selecting another rail and allowing the next gear engagement. The Shift Bar Housing Interlock physically prevents the engagement of two gears at the same time.
Fault Code 72 sets when the X-Y Shift Finger attempts to move to a different rail position, but the X-Y Rail Position Sensor indicates that the transmission was unable to select the next rail position. Transmission Electronic Control Unit (TECU) detected a system failure, but was unable to detect the specific root cause.
Detection:
This fault can only be detected when there are no failures of the TECU, X-Y Gear or Rail Motors, X-Y Position Sensors or Battery Supply voltage. This fault code is set when the system
is unable to move to a different rail position and the transmission is not engaged in a gear.
Conditions to Set Fault Code Active:
FMI 7 – Mechanical System Not Responding: After being unable to select a rail position for 2 seconds, the fault code sets Active.
Fallback:
FMI 7:
• Transmission may not be able to complete a shift to the proper rail.
• Transmission will attempt to move the Shift Finger to the proper rail.
• Gear display may flash current or destination gear.
Conditions to Set Fault Code Inactive:
FMI 7: The system successfully positions the Shift Finger on the proper rail.
Possible Causes:
FMI 7:
1) Vehicle Power Supply
– Poor power or ground supply to TECU
– Bent, spread, corroded or loose terminals
2) Vehicle Batteries
– Internal failure
3) Transmission Harness
– Damaged wiring between the TECU and X-Y Shifter
– Bent, spread, corroded or loose terminals
4) X-Y Shifter
– Worn or damaged X-Y Shifter ball screw, center shaft bushing, or other internal components
– Contaminated X-Y Shifter ball screw due to coolant leak or oil contamination
– Bent, spread, corroded or loose terminals
5) Mechanical Transmission
– Worn or damaged Shift Bar Housing
– Worn Sliding Clutch slot width
– Worn or damaged Shift Yokes
– Worn or damaged internal transmission components
Related
-
premium volvo tech tool update 2.8.150 diagnostic software 1pc
Trucks software $150.00Rated 0 out of 5 -
VOLVO PREMIUM TECH TOOL PTT 2.7.30 Developer + Devtool + INSTALATION VIDEO!
Trucks software $60.00Rated 0 out of 5 -
10 IN 1 FOR CAT SIS Caterpillar 2021 Full Service Dealer INCLUDING CAT 2019 C
CAT $110.00Rated 0 out of 5
-
Eaton Service Ranger 4.9 Engineering 4.9 [05.2021] Engineering Level ( 1 PC )
Eaton $67.00Rated 0 out of 5 -
Volvo Premium Tech Tool PTT 2.8.130 Diagnostic Software 04.2022 ACPI ( 1 PC )
Trucks software $143.00Rated 0 out of 5
Related products
-
Allison 1000 & 2000 Gen 4 Fault Codes: U1301 J1850 (Class 2) Serial Data Communication Link Low
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1000 Class 2 Loss of Serial Data Communication
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0872 Transmission Pressure Switch Solenoid E Circuit Stuck Closed
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P2771 Four-Wheel Drive Switch Circuit
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0847 Transmission Pressure Switch Solenoid D Circuit Stuck Closed
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U2105 CAN Bus ECM Error
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0876 Transmission Reverse Pressure Switch Circuit Stuck Open
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0123 Pedal Position Sensor Circuit High Voltage
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1300 J1850 (Class 2) Serial Data Communication Link Low
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P1891 Engine Throttle Position Sensor Pulse Width Modulation (PWM) Signal Low Input
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0873 Transmission Pressure Switch Solenoid E Circuit High
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P2773 Torque Control Request Ignored – ECM/TCM
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P1892 Throttle Position Sensor Pulse Width Modulation (PWM) Signal High Input
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0880 TCM Supply Voltage
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0870 Transmission Pressure Switch Solenoid E Circuit
1000 & 2000 Gen 4 $50.00Rated 0 out of 5
-
SERVICE MANUAL International Engines MaxxForce 7 (2007-2009)
INTERNATIONAL ENGINES $31.00Rated 0 out of 5 -
SERVICE MANUAL International Engines DT466E & DT530E (1999 & Older)
INTERNATIONAL ENGINES $31.00Rated 0 out of 5 -
SERVICE MANUAL International Engines DT466 & DT530 (1995-1998)
INTERNATIONAL ENGINES $34.00Rated 0 out of 5