Detroit DD16 GHG14 (2014-16) Fault Code: SPN 706 FMI 5 (CPC) Digital Output 3 10 Circuit Open

DESCRIPTION:
CPC output 3 10 open circuit.

MONITORED PARAMETER:
CPC output 3/10.

TYPICAL ENABLING CONDITIONS:
Always enabled

MONITOR SEQUENCE:
None

EXECUTION FREQUENCY:
Always enabled

TYPICAL DURATION:
Two seconds

DASH LAMPS:
CEL

ENGINE REACTION:
None

VERIFICATION:
Engine on with output activation.

NOTE: Pin 10 of the CPC4 #3 connector has a wiring problem.