Detroit DD16 EPA10 (2010-13) Fault Code: SPN 705 FMI 4 (CPC) Digital Output 1 13 Circuit Failed Low

DESCRIPTION:
CPC output 1 13 short to ground.

MONITORED PARAMETER:
CPC output 1/13.

TYPICAL ENABLING CONDITIONS:
Always enabled

MONITOR SEQUENCE:
None

EXECUTION FREQUENCY:
Always enabled

TYPICAL DURATION:
Two seconds

DASH LAMPS:
CEL

ENGINE REACTION:
None

VERIFICATION:
Engine on with output activation.

NOTE: Pin 13 of the CPC #1 connector has a wiring problem.