Detroit DD15 EPA07 (2007-09) Fault Code: SPN 247 FMI 1 (CPC) MCM Engine Hours Data Lower than Expected

NOTE: The common powertrain controller (CPC) digital outputs have the SPN as some motor control module (MCM) faults. The diagnostic service tool makes the distinction between the MCM and CPC when diagnosing a fault.

NOTE: This diagnostic is typically MCM engine hours data lower than expected. This fault usually occurs after reprogramming the CPC or MCM. The internal clocks of the CPC or MCM do not match. After reprogramming either module, all fault codes must be cleared.

NOTE: This error usually occurs after an improper ECM programming. ECM must be programmed correctly, most often the internal clocks don’t match.