Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6794 PID: SPN: 7854 FMI: 2/21 Aftertreatment 1 Particulate Sensor Module – Data Not Rational – Drifted Low
Lamp:
None
Reason:
An offset in the particulate matter sensor reading has been detected.
Effect:
Possible reduced engine performance.
The aftertreatment particulate matter sensor is a smart device and communicates with the Engine Control Module (ECM) via the J1939 data link.
Circuit Description:
The aftertreatment particulate matter sensor is a smart device and communicates with the Engine Control Module (ECM) via the J1939 data link. The aftertreatment particulate matter sensor performs internal diagnostics and reports malfunctions back to the primary ECM using the J1939 data link. The particulate matter sensor is permanently attached to the particulate matter control module. They are serviced as a single component and can not be replaced individually. The aftertreatment particulate matter sensor is used to measure the soot emissions at the outlet of the aftertreatment system.
Component Location:
The aftertreatment particulate matter sensor location can vary depending on engine application. It is usually located in the exhaust system at the outlet of the Selective Catalytic Reduction (SCR) catalyst.
Conditions for Running the Diagnostics:
This diagnostic runs continuously when the engine is running.
Conditions for Setting the Fault Codes:
The aftertreatement particulate matter sensor has detected the probe temperature value is not changing with conditions.
Action Taken When the Fault Code is Active:
The ECM illuminates the amber check engine lamp and/or Malfunction Indicator Lamp (MIL) after the diagnostic fails on two consecutive trips.
Conditions for Clearing the Fault Code:
1. Perform a key cycle.
2. Start and idle the engine.
3. To validate the repair, use the diagnostic tool to perform the “aftertreatment current based particulate matter sensor regeneration test” found in ECM diagnostic test.
4. The ECM will turn off the amber check engine lamp immediately after the diagnostic runs and passes.
5. The fault code status displayed by the diagnostic tool will change to inactive immediately after the diagnostic runs and passes.
6. For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.
7. The reset all faults command in the diagnostic tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.
Shop Talk:
Possible causes for this fault include:
Malfunctioning aftertreatment particulate matter sensor.
-
Hino Diagnostic eXplorer 2 – Hino DX2 1.1.19.1 with keygen unlocked ( Hino trucks )
Hino $50.00Rated 0 out of 5 -
International Truck ISIS – Oncommand Service Information Q4.2020 [04.2020]
Navistar $85.00Rated 0 out of 5
Related products
-
Allison 1000 & 2000 Gen 4 Fault Codes: U2104 CAN Bus Reset Counter Overrun
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U0073 CAN Bus Reset Counter Overrun
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U0100 CAN Bus ECM Error
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1300 J1850 (Class 2) Serial Data Communication Link Low
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0122 Pedal Position Sensor Circuit Low Voltage
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0880 TCM Supply Voltage
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P2771 Four-Wheel Drive Switch Circuit
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U0031 J1850 (Class 2) Serial Data Communication Link Low
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P1892 Throttle Position Sensor Pulse Width Modulation (PWM) Signal High Input
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0872 Transmission Pressure Switch Solenoid E Circuit Stuck Closed
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0871 Transmission Pressure Switch Solenoid E Circuit Stuck Open
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0848 Transmission Pressure Switch Solenoid D Circuit High
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0873 Transmission Pressure Switch Solenoid E Circuit High
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1301 J1850 (Class 2) Serial Data Communication Link Low
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P2773 Torque Control Request Ignored – ECM/TCM
1000 & 2000 Gen 4 $50.00Rated 0 out of 5
-
SERVICE MANUAL Eaton Fuller® HD FR/FRO TransmissionsTRSM2400April 2013
TRUCK MANUALSRated 0 out of 5 -
SERVICE MANUAL Carrie Starbird TDB/TDS-215 and Starbird PlusTDB/TDS-219
CARRIE $24.00Rated 0 out of 5