Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6793 PID: SPN: 7854 FMI: 2/20 Aftertreatment 1 Particulate Sensor Module – Data Not Rational – Drifted High
Lamp:
None
Reason:
An offset in the particulate matter sensor reading has been detected.
Effect:
Possible reduced engine performance.
Circuit Description:
The aftertreatment particulate matter sensor is a smart device and communicates with the Engine Control Module (ECM) via the J1939 data link. The aftertreatment particulate matter sensor performs internal diagnostics and reports malfunctions back to the primary ECM using the J1939 data link. The particulate matter sensor is permanently attached to the particulate matter control module. They are serviced as a single component and can not be replaced individually. The aftertreatment particulate matter sensor is used to measure the soot emissions at the outlet of the aftertreatment system.
Component Location:
The aftertreatment particulate matter sensor location can vary depending on engine application. It is usually located in the exhaust system at the outlet of the Selective Catalytic Reduction (SCR) catalyst.
Conditions for Running the Diagnostics:
This diagnostic runs continuously when the engine is running.
Conditions for Setting the Fault Codes:
The aftertreatment particulate matter sensor has detected the probe temperature value is not changing with conditions.
Action Taken When the Fault Code is Active:
The ECM illuminates the amber check engine lamp and/or Malfunction Indicator Lamp (MIL) after the diagnostic fails on two consecutive trips.
Conditions for Clearing the Fault Code:
1. Perform a key cycle.
2. Start and idle the engine.
3. To validate the repair, use the diagnostic tool to perform the “aftertreatment current based particulate matter sensor degeneration test” found in ECM diagnostic test.
4. The ECM will turn off the amber check engine lamp immediately after the diagnostic runs and passes.
5. The fault code status displayed by the diagnostic tool will change to inactive immediately after the diagnostic runs and passes.
6. For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.
7. The reset all faults command in the diagnostic tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.
Shop Talk:
Possible causes for this fault include:
Malfunctioning aftertreatment particulate matter sensor.
-
DETROIT DDDL 8.14 SP3 – Detroit Diesel Diagnostic Link 8.14 SP3 2021 ( 1PC )
Detroit $73.00Rated 0 out of 5 -
Hino Diagnostic eXplorer 2 – Hino DX2 1.1.19.1 with keygen unlocked ( Hino trucks )
Hino $50.00Rated 0 out of 5
-
DOWNLOAD Paccar ESA Electronic Service Analyst 5.5.0 Diagnostic Software 2023
PACCAR $96.00Rated 0 out of 5 -
Wabco ToolBox plus 13.7.0.1 + ECAS CAN2 v3.00 Diagnostics Software
Trucks software $84.00Rated 0 out of 5 -
DPF EGR SCR BAC ERG Delete & Flash CAAT Cummings Detroit Dodge Mack Volvo Collection of DELETE files
CAT $200.00Rated 0 out of 5 -
International Truck ISIS – Oncommand Service Information Q4.2020 [04.2020]
Navistar $85.00Rated 0 out of 5
Related products
-
Allison 1000 & 2000 Gen 4 Fault Codes: U0032 J1850 (Class 2) Serial Data Communication Link High
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1064 J1850 (Class 2) TBC Controller State of Health Failure
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U0073 CAN Bus Reset Counter Overrun
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U0031 J1850 (Class 2) Serial Data Communication Link Low
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0873 Transmission Pressure Switch Solenoid E Circuit High
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0872 Transmission Pressure Switch Solenoid E Circuit Stuck Closed
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1000 Class 2 Loss of Serial Data Communication
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1096 J1850 (Class 2) IPC Controller State of Health Failure
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0218 Transmission Fluid Over Temperature Condition
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1301 J1850 (Class 2) Serial Data Communication Link Low
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0871 Transmission Pressure Switch Solenoid E Circuit Stuck Open
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0875 Transmission Reverse Pressure Switch Circuit Malfunction
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P2771 Four-Wheel Drive Switch Circuit
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U0100 CAN Bus ECM Error
1000 & 2000 Gen 4 $50.00Rated 0 out of 5
-
SERVICE MANUAL INTERNATIONAL ENGINE VT275 (2005 & Newer)
INTERNATIONAL ENGINES $27.00Rated 0 out of 5