Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3228 PID: SPN: 3216 FMI: 2 Aftertreatment 1 Intake Nox Sensor- Data Erratic, Intermittent, or Incorrect
Circuit Description
The aftertreatment intake NOx (nitrogen oxides) sensor is a smart device and communicates with the engine control module (ECM) via the J1939 data link. The aftertreatment intake NOx sensor performs internal diagnostics and reports malfunctions back to the primary ECM using the J1939 data link. The NOx sensor is permanently attached to the NOx control module. They are serviced as a single component and can not be replaced individually. The aftertreatment intake NOx sensor is used to measure the NOx emissions at the intake of the aftertreatment system.
Component Location
The aftertreatment intake NOx sensor is mounted on the engine near the turbocharger turbine outlet.
Conditions for Running the Diagnostics
This diagnostic runs when the aftetreatment diesel oxidation catalsyst intake temperature sensor has been above 150° C [302° F] for 5 seconds while the engine is running.
This diagnostic has to meet specific engine and aftertreatment conditions to run and complete.
Conditions for Setting the Fault Codes
The Engine Control Module (ECM) detected the aftertreatment intake NOx reading was higher or lower than the calculated aftertreatment intake NOx value for the engine operating conditions.
Action Taken When the Fault Code is Active
The ECM illuminates the amber CHECK ENGINE lamp and/or Malfunction Indicator Lamp (MIL) after the diagnostic fails on two consecutive trips.
Conditions for Clearing the Fault Code
To validate the repair, it may be necessary to operate the vehicle on a chassis dynamometer or to drive the vehicle in order to get the engine load high enough for the diagnostic to run.
The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.
The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.
For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.
The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.
Shop Talk
Possible causes of this fault code include:
EGR system leaks
Exhaust system leaks
An incorrectly installed aftertreatment intake NOx sensor
An aftertreatment intake NOx sensor that has carbon buildup on the tip of the sensor
A malfunctioning EGR differential pressure sensor.
A malfunctioning EGR valve
Excessive oil consumption
Possible engine misfire
The NOx sensor part number is incorrect.
Possible Cause:
1) N/A
Related
-
2021 VOLVO PREMIUM TECH TOOL PTT V2.8.21 VCADS+DEVELOPER TOOL+APCI 2021/09 ( 1 PC )
Trucks software $85.00Rated 0 out of 5 -
VOLVO PREMIUM TECH TOOL PTT 2.7.30 Developer + Devtool + INSTALATION VIDEO!
Trucks software $60.00Rated 0 out of 5
Related products
-
Allison 1000 & 2000 Gen 4 Fault Codes: U1300 J1850 (Class 2) Serial Data Communication Link Low
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0848 Transmission Pressure Switch Solenoid D Circuit High
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0846 Transmission Pressure Switch Solenoid D Circuit Stuck Open
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1064 J1850 (Class 2) TBC Controller State of Health Failure
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P1892 Throttle Position Sensor Pulse Width Modulation (PWM) Signal High Input
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1000 Class 2 Loss of Serial Data Communication
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U0100 CAN Bus ECM Error
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U2104 CAN Bus Reset Counter Overrun
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1041 J1850 (Class 2) ABS Controller State of Health Failure
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1301 J1850 (Class 2) Serial Data Communication Link Low
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1096 J1850 (Class 2) IPC Controller State of Health Failure
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0870 Transmission Pressure Switch Solenoid E Circuit
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P2773 Torque Control Request Ignored – ECM/TCM
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1016 Class 2 J1850 (Class 2) Powertrain Controller State of Health Failure
1000 & 2000 Gen 4 $50.00Rated 0 out of 5
-
SERVICE MANUAL International Engines MaxxForce 5 (2007 & 2009)
INTERNATIONAL ENGINES $25.00Rated 0 out of 5