Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2288 PID: PID 103 SPN: 103 FMI: 15 Turbocharger 1 Speed- Data Valid But Above Normal Operating Range- Least Severe Level

Circuit Description
The turbocharger speed sensor is a variable reluctance speed sensor. It consists of a coil of wire and an iron core. The target on the turbocharger shaft is a ground flat in the center of the shaft. As the flat on the turbocharger shaft spins past the speed sensor, a signal is generated. The Engine Control Module (ECM) interprets this signal and converts it to a turbocharger speed reading.

Component Location
The turbocharger speed sensor is mounted in the center housing of the turbocharger.

Conditions for Running the Diagnostics
This diagnostic runs continuously when the engine is running.

Conditions for Setting the Fault Codes
The Engine Control Module (ECM) detected the turbocharger speed was above the maximum calibratible limits.

Action Taken When the Fault Code is Active
The ECM logs the fault code immediately when the diagnostic runs and fails.
The ECM will reduce the torque output of the engine to reduce turbocharger speeds.
Conditions for Clearing the Fault Code
To validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.
The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.
The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.
The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop Talk
When the engine has taken the necessary action to reduce the turbocharger speed, this fault code is logged. This fault code is for information only and no repairs are necessary. The engine can possibly be derated when operating near the maximum turbocharger speed limits.

Possible Cause:
1) ECM calibration