Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6463 PID: SPN: 3226 FMI: 2/21 Aftertreatment 1 Outlet NOx Sensor – Data Not Rational – Drifted Low
Lamp:
None
Reason:
An offset in the outlet NOx sensor reading has been detected.
Effect:
None on performance.
Circuit Description:
The aftertreatment outlet NOx (Nitrogen Oxides) sensor is a smart device and communicates with the Engine Control Module (ECM) via the J1939 data link. The aftertreatment outlet NOx sensor performs its own internal diagnostics and reports malfunctions back to the primary ECM using the J1939 data link. The NOx sensor is permanently attached to the NOx control module. They are serviced as a single component and can not be replaced individually. The aftertreatment outlet NOx sensor is used to measure the NOx emissions at the outlet of the aftertreatment system.
Component Location:
The aftertreatment outlet NOx sensor location can vary depending on engine application. It is usually located in the exhaust system at the outlet of the Selective Catalytic Reduction (SCR) catalyst.
Conditions for Running the Diagnostics:
This diagnostic runs when the aftertreatment SCR outlet temperature is above 200°C [392°F], and the engine is in a motoring condition.
Conditions for Setting the Fault Code:
The Engine Control Module (ECM) detected the aftertreatment outlet NOx sensor was not reading zero while in a motoring (non-fueling) condition.
Action Taken When the Fault Code is Active:
The ECM illuminates the amber check engine lamp and/or Malfunction Indicator Lamp (MIL) after the diagnostic fails on two consecutive trips.
Conditions for Clearing the Fault Code:
1. Start and operate the engine to raise exhaust temperatures. This can be done by either driving the vehicle or initiating a stationary regeneration using the recommended diagnostic tool or equivalent.
2. The aftertreatment SCR outlet temperature must be above 200°C [392°F] for 60 seconds before the aftertreatment outlet NOx sensor can run its internal diagnostics.
3. To validate the repair, it is necessary to drive the vehicle and operate it in a motoring condition for 10 seconds continuously.
4. The fault code status displayed by the recommended diagnostic tool or equivalent will change to inactive immediately after the diagnostic runs and passes.
5. The ECM will turn off the amber check engine lamp immediately after the diagnostic runs and passes.
6. For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.
7. The “reset all faults” command in the recommended diagnostic tool or equivalent can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.
Shop Talk:
Possible causes of this fault code include:
1. Malfunctioning aftertreatment outlet NOx sensor.
2. Diesel exhaust fluid crystallization or deposits.
3. Improperly installed aftertreatment outlet NOx sensor.
4. Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.
5. For intermittent power supply and datalink. communication issues with aftertreatment components, it is highly recommended that the OEM power distribution center fuses and relays be thoroughly checked for loose, missing or intermittent connections.
-
Volvo PROSIS Offline 2019 Parts Catalog Installation Service
Trucks software $45.00Rated 0 out of 5
-
Bobcat Service Library [03.2019] Service, Operator, Maintenance, Bulletines, etc full update
Bobcat $110.00Rated 0 out of 5 -
Navistar international OnCommand service information 2018 software trucks
Navistar $50.00Rated 0 out of 5 -
DAF Davie Runtime v5.6.1 Davie XDc ll [02.2019] + Expire Fix 302.00 Unlock ( Windows 7 )
DAF $70.00Rated 0 out of 5 -
CAT CDVR PC Software – Caterpillar Digital Voltage Regulator (CDVR) WINDOWS 10
CAT $45.00Rated 0 out of 5 -
John Deere & Hitachi Parts ADVISOR 2020 [08.2020] Offline DVD Spare Parts Catalog
John Deere $120.00Rated 0 out of 5 -
Volvo PROSIS Offline 2019 Parts Catalog Installation Service
Trucks software $45.00Rated 0 out of 5
Related products
-
Allison 1000 & 2000 Gen 4 Fault Codes: P0870 Transmission Pressure Switch Solenoid E Circuit
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U2104 CAN Bus Reset Counter Overrun
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1000 Class 2 Loss of Serial Data Communication
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0872 Transmission Pressure Switch Solenoid E Circuit Stuck Closed
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P2773 Torque Control Request Ignored – ECM/TCM
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U2105 CAN Bus ECM Error
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0122 Pedal Position Sensor Circuit Low Voltage
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P1892 Throttle Position Sensor Pulse Width Modulation (PWM) Signal High Input
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1016 Class 2 J1850 (Class 2) Powertrain Controller State of Health Failure
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P1688 Unmanaged Engine Torque Delivered To TCM Signal
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0123 Pedal Position Sensor Circuit High Voltage
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U0073 CAN Bus Reset Counter Overrun
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1064 J1850 (Class 2) TBC Controller State of Health Failure
1000 & 2000 Gen 4 $50.00Rated 0 out of 5
-
SERVICE MANUAL International Engines MaxxForce 7 (2010 & Newer)
INTERNATIONAL ENGINES $34.00Rated 0 out of 5 -
SERVICE MANUAL International Engines MaxxForce 7 (2007-2009)
INTERNATIONAL ENGINES $31.00Rated 0 out of 5 -
SERVICE MANUAL International Engines DT466 & DT530 (1995-1998)
INTERNATIONAL ENGINES $34.00Rated 0 out of 5