Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 5935 PID: SPN: 4334 FMI: 7/7 Aftertreatment 1 Diesel Exhaust Fluid Pressure – Mechanical System Not Responding or Out of Adjustment
Lamp:
Amber
Reason:
The diesel exhaust pressure sensor is reading erratic.
Effect:
Possible reduced engine performance.
Circuit Description:
The aftertreatment diesel exhaust fluid dosing valve is controlled by the ECM. When the Engine Control Module (ECM) commands DEF dosing, the ECM sends a Pulse-Width Modulated (PWM) signal to the dosing valve, which opens the dosing valve and allows DEF to be sprayed into the exhaust stream.
Component Location:
The aftertreatment diesel exhaust fluid dosing valve is installed in the exhaust system. It is mounted directly to the aftertreatment decomposition tube, before the Selective Catalytic Reduction (SCR) catalyst. Installation position will vary, based on the aftertreatment architecture and the Original Equipment Manufacturer (OEM).
Conditions for Running the Diagnostics:
This diagnostic runs when the diesel exhaust fluid dosing valve is being commanded on.
Conditions for Setting the Fault Code:
The Engine Control Module (ECM) detected the aftertreatment diesel exhaust fluid dosing valve is mechanically stuck.
Action Taken When the Fault Code is Active:
The ECM illuminates the amber check engine lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.
Conditions for Clearing the Fault Code:
It may be necessary to perform both validations to clear this fault:
1. To validate the repair, perform the “aftertreatment diesel exhaust fluid doser pump override test” found under “ECM diagnostic tests” in the recommended diagnostic tool or equivalent.
2. To validate the repair, key OFF for 1 minute, then key ON for 1 minute.
3. The fault code status displayed by the recommended diagnostic tool or equivalent will change to inactive immediately after the diagnostic runs and passes.
4. The ECM will turn off the amber check engine lamp immediately after the diagnostic runs and passes.
5. The “reset all faults” command in the recommended diagnostic tool or equivalent can be used to clear active and inactive faults.
Shop Talk:
Possible causes of this fault code include:
1. A malfunctioning aftertreatment diesel exhaust fluid dosing valve.
2. Blocked, restricted, or frozen diesel exhaust fluid dosing valve return line or return line connector.
Related
-
2021 VOLVO PREMIUM TECH TOOL PTT V2.8.21 VCADS+DEVELOPER TOOL+APCI 2021/09 ( 1 PC )
Trucks software $85.00Rated 0 out of 5 -
Wabco ToolBox plus 13.7.0.1 + ECAS CAN2 v3.00 Diagnostics Software
Trucks software $84.00Rated 0 out of 5
Related products
-
Allison 1000 & 2000 Gen 4 Fault Codes: P0847 Transmission Pressure Switch Solenoid D Circuit Stuck Closed
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0122 Pedal Position Sensor Circuit Low Voltage
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U0032 J1850 (Class 2) Serial Data Communication Link High
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P1688 Unmanaged Engine Torque Delivered To TCM Signal
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0846 Transmission Pressure Switch Solenoid D Circuit Stuck Open
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0875 Transmission Reverse Pressure Switch Circuit Malfunction
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0873 Transmission Pressure Switch Solenoid E Circuit High
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1064 J1850 (Class 2) TBC Controller State of Health Failure
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0123 Pedal Position Sensor Circuit High Voltage
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0880 TCM Supply Voltage
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1016 Class 2 J1850 (Class 2) Powertrain Controller State of Health Failure
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1041 J1850 (Class 2) ABS Controller State of Health Failure
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1096 J1850 (Class 2) IPC Controller State of Health Failure
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U0073 CAN Bus Reset Counter Overrun
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1300 J1850 (Class 2) Serial Data Communication Link Low
1000 & 2000 Gen 4 $50.00Rated 0 out of 5
-
SERVICE MANUAL International Engines DT466 & DT530 (1995-1998)
INTERNATIONAL ENGINES $34.00Rated 0 out of 5