Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 5865 PID: SPN: 4375 FMI: 4/4 Aftertreatment 1 Diesel Exhaust Fluid Pump Command Circuit – Voltage Below Normal or Shorted to Low Source
Lamp:
Amber
Reason:
A short circuit to ground has been detected in the diesel exhaust fluid pump command circuit.
Effect:
Possible reduced engine performance.
Circuit Description:
The dosing unit relay provides a battery voltage supply to the diesel exhaust fluid dosing unit. The ECM supplies a signal to the dosing unit to control the diesel exhaust fluid output. This signal changes, based on the diesel exhaust fluid pressure being commanded.
Component Location:
The aftertreatment diesel exhaust fluid dosing unit location is original equipment manufacturer (OEM) dependent.
Conditions for Running the Diagnostics:
This diagnostic runs when the aftertreatment diesel exhaust fluid dosing unit is commanded OFF.
Conditions for Setting the Fault Code:
The Engine Control Module (ECM) detected voltage below a calibrated value on the control circuit when the dosing unit was commanded OFF.
Action Taken When the Fault Code is Active:
1. The ECM illuminates the amber check engine lamp immediately when the diagnostic runs and fails.
2. Engine torque will be severely reduced if the engine is operated for an extended period of time with this fault active.
Conditions for Clearing the Fault Code:
1. To validate the repair, start the engine and let it idle for 1 minute.
2. The ECM will turn off the amber check engine lamp immediately after the diagnostic runs and passes.
3. The fault code status displayed by the recommended diagnostic tool or equivalent will change to inactive immediately after the diagnostic runs and passes.
4. The “reset all faults” command in the recommended diagnostic tool or equivalent can be used to clear active and inactive faults.
Shop Talk:
Possible causes of this fault code include:
A short circuit to ground in the OEM wiring harness.
-
Navistar international OnCommand service information 2018 software trucks
Navistar $50.00Rated 0 out of 5
-
Navistar international OnCommand service information 2018 software trucks
Navistar $50.00Rated 0 out of 5 -
Volvo Impact 2021 Trucks & Buses 06.2021 DVD 9116 Spare Parts Catalog
Trucks software $55.00Rated 0 out of 5
Related products
-
Allison 1000 & 2000 Gen 4 Fault Codes: U1064 J1850 (Class 2) TBC Controller State of Health Failure
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1000 Class 2 Loss of Serial Data Communication
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1301 J1850 (Class 2) Serial Data Communication Link Low
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 P0719 Brake Switch ABS Input Low
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P1779 Engine Torque Delivered To TCM Signal
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P2773 Torque Control Request Ignored – ECM/TCM
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P2810 Solenoid G Electrical
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0122 Pedal Position Sensor Circuit Low Voltage
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0123 Pedal Position Sensor Circuit High Voltage
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U2105 CAN Bus ECM Error
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U0031 J1850 (Class 2) Serial Data Communication Link Low
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U0073 CAN Bus Reset Counter Overrun
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0873 Transmission Pressure Switch Solenoid E Circuit High
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1096 J1850 (Class 2) IPC Controller State of Health Failure
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0847 Transmission Pressure Switch Solenoid D Circuit Stuck Closed
1000 & 2000 Gen 4 $50.00Rated 0 out of 5
-
SERVICE MANUAL International Engines MaxxForce 11 & 13 (2014 & Newer)
INTERNATIONAL ENGINES $20.00Rated 0 out of 5 -
SERVICE MANUAL DETROIT DIESEL EPA 07, EPA 10, GHG 14 TROUBLESHOOTING
DETROIT $38.00Rated 0 out of 5