Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 2554 PID: PID 131 SPN: 1209 FMI: 2 Exhaust Gas Pressure- Data Erratic, Intermittent, or Incorrect

Circuit Description
The exhaust gas pressure sensor is used to measure exhaust gas pressure in the exhaust manifold. This information is used by the engine control module (ECM) to control emissions and exhaust gas recirculation (EGR) valve operation. The ECM provides a 5 volt supply to the exhaust gas pressure sensor on the sensor supply circuit. The ECM also provides a ground on the sensor return circuit. The exhaust gas pressure sensor provides a signal to the ECM on the exhaust gas pressure sensor signal circuit. This sensor signal voltage changes, based on the pressure in the exhaust manifold.

Component Location
The exhaust gas pressure sensor is located above the front section of the exhaust manifold and is plumbed into the exhaust manifold.

Conditions for Running the Diagnostics
This diagnostic consists of two parts:

One part runs immediately after the keyswitch is turned OFF, and the engine coolant temperature is above 70°C or 158°F.

The second part runs continuously while the engine is running.
Conditions for Setting the Fault Codes
The Engine Control Module (ECM) detected the exhaust pressure reading was higher or lower than the other absolute pressure sensors when the keyswitch is OFF and the engine is not running.
The Engine Control Module (ECM) detected the exhaust pressure was higher or lower than expected during normal engine operation.
Action Taken When the Fault Code is Active
The ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.
A default value is used for the exhaust gas pressure sensor reading.
Exhaust Gas Recirculation (EGR) valve operation will be disabled.
Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.
Conditions for Clearing the Fault Code
To validate the repair, first ensure the engine coolant temperature is above 70°C or 158°F. Operate the engine if necessary.
Cycle the keyswitch to the ON position for 30 seconds, then cycle the keyswitch to the OFF position for 30 seconds. Start the engine and run it at high idle for up to 5 minutes.
The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.
The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.
For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.
The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop Talk
Possible causes of this fault code include:

Stuck in-range exhaust gas pressure sensor reading
High resistance in the exhaust gas pressure sensor signal or return lines
Plugging or restriction in the exhaust gas pressure sensor tube
Leaks in the exhaust system

Possible Cause:
1) Engine harness
2) ECM calibration