Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 7935 PID: SPN: 412 FMI: 10/10 Engine Exhaust Gas Recirculation 1 Temperature – Abnormal Rate of Change
Lamp:
Amber
Reason:
The EGR temperature sensor is reading an erratic value at initial key ON or while the engine is running.
Effect:
Possible reduced engine performance.
Circuit Description:
The Exhaust Gas Recirculation (EGR) temperature sensor is a variable resistor sensor and is used to measure the temperature of the EGR gas flow after it exits the EGR cooler. The Engine Control Module (ECM) supplies 5 volts to the EGR temperature signal circuit. The ECM monitors the change in voltage caused by changes in the resistance of the sensor to determine the EGR flow temperature.
The EGR temperature value is used by the ECM for the engine protection system and engine emissions control.
Component Location:
The EGR temperature sensor is located on the EGR connection tube between the EGR cooler and the air intake connection.
Conditions for Running the Diagnostic:
The engine must be turned OFF for period of 8 hours before this diagnostic will run. This diagnostic runs when the keyswitch is turned to the ON position after an 8 hour cold soak.
Conditions for Setting the Fault Codes:
The Engine Control Module (ECM) detected the EGR temperature reading was higher or lower than the other temperature sensors on the engine after an extended period of engine off time.
Action Taken When the Fault Code is Active:
1. The ECM illuminates the amber check engine lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.
2. Diesel exhaust fluid injection into the aftertreatment system is disabled.
3. Active and stationary regeneration of the diesel particulate filter will be disabled.
4. Exhaust gas recirculation (EGR) valve operation will be disabled.
5. Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.
Conditions for Clearing the Fault Code:
1. To validate the repair, the engine must be shut down with the keyswitch in the OFF position for 8 hours. After the 8 hour cold soak turn the keyswitch to the ON position for 30 seconds.
2. The fault code status displayed by the recommended diagnostic tool or equivalent will change to inactive immediately after the diagnostic runs and passes.
3. The ECM will turn off the amber check engine lamp immediately after the diagnostic runs and passes.
4. For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.
5. The “reset all faults” command in the recommended diagnostic tool or equivalent can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.
Shop Talk:
Possible causes of this fault code include:
1. Stuck in-range EGR temperature sensor.
2. High resistance in the EGR temperature sensor signal or return wires.
-
Hino Diagnostic eXplorer 2 – Hino DX2 1.1.19.1 with keygen unlocked ( Hino trucks )
Hino $50.00Rated 0 out of 5
-
JOHN DEERE SERVICE ADVISOR 5.3.225 DATABASE AG + CF ENGLISH 2023
John Deere $250.00Rated 0 out of 5 -
Wabco ToolBox plus 13.7.0.1 + ECAS CAN2 v3.00 Diagnostics Software
Trucks software $84.00Rated 0 out of 5 -
CAT ET 2021A (Caterpillar Electronic Technician) + Factory Password (1 PC )
CAT $65.00Rated 0 out of 5 -
Eaton Service Ranger 4.9 Engineering 4.9 [05.2021] Engineering Level ( 1 PC )
Eaton $67.00Rated 0 out of 5 -
DETROIT DDDL 8.14 SP3 – Detroit Diesel Diagnostic Link 8.14 SP3 2021 ( 1PC )
Detroit $73.00Rated 0 out of 5
Related products
-
Allison 1000 & 2000 Gen 4 Fault Codes: P0123 Pedal Position Sensor Circuit High Voltage
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P2810 Solenoid G Electrical
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1096 J1850 (Class 2) IPC Controller State of Health Failure
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0871 Transmission Pressure Switch Solenoid E Circuit Stuck Open
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0848 Transmission Pressure Switch Solenoid D Circuit High
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P2773 Torque Control Request Ignored – ECM/TCM
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0872 Transmission Pressure Switch Solenoid E Circuit Stuck Closed
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U0032 J1850 (Class 2) Serial Data Communication Link High
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0880 TCM Supply Voltage
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1000 Class 2 Loss of Serial Data Communication
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0847 Transmission Pressure Switch Solenoid D Circuit Stuck Closed
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P1688 Unmanaged Engine Torque Delivered To TCM Signal
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U2104 CAN Bus Reset Counter Overrun
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0875 Transmission Reverse Pressure Switch Circuit Malfunction
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U2105 CAN Bus ECM Error
1000 & 2000 Gen 4 $50.00Rated 0 out of 5
-
SERVICE MANUAL International Engines DT466 & DT530 (2001-2003) C
INTERNATIONAL ENGINES $31.00Rated 0 out of 5