Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 7864 PID: SPN: 1209 FMI: 10/10 Exhaust Gas Pressure – Abnormal Rate of Change
Lamp:
Amber
Reason:
The exhaust gas pressure sensor is reading an erratic value.
Effect:
Possible reduced engine performance.
Circuit Description:
The exhaust gas pressure sensor is used to measure exhaust gas pressure in the exhaust manifold. This information is used by the Engine Control Module (ECM) to control emissions and Exhaust Gas Recirculation (EGR) valve operation. The ECM provides a 5 volt supply to the exhaust gas pressure sensor on the sensor supply circuit. The ECM also provides a ground on the sensor return circuit. The exhaust gas pressure sensor provides a signal to the ECM on the exhaust gas pressure sensor signal circuit. This sensor signal voltage changes, based on the pressure in the exhaust manifold.
Component Location:
The exhaust gas pressure sensor is located above the front section of the exhaust manifold and is plumbed into the exhaust manifold.
Conditions for Running the Diagnostic:
This diagnostic runs immediately after the keyswitch is turned OFF, and the engine coolant temperature is above 70°C or 158 °F.
Conditions for Setting the Fault Codes:
The Engine Control Module (ECM) detected the exhaust pressure reading was higher or lower than the other absolute pressure sensors when the keyswitch is OFF and the engine is not running.
Action Taken When the Fault Code is Active:
1. The ECM illuminates the amber check engine lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.
2. A default value is used for the exhaust gas pressure sensor reading.
3. Exhaust Gas Recirculation (EGR) valve operation will be disabled.
4. Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.
Conditions for Clearing the Fault Code:
1. To validate the repair, first ensure the engine coolant temperature is above 70°C or 158°F. Operate the engine if necessary.
2. Cycle the keyswitch to the ON position for 30 seconds, then cycle the keyswitch to the OFF position for 30 seconds. Start the engine and run it at high idle for up to 5 minutes.
3. The fault code status displayed by the recommended diagnostic tool or equivalent will change to inactive immediately after the diagnostic runs and passes.
4. The ECM will turn off the amber check engine lamp immediately after the diagnostic runs and passes.
5. For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.
6. The “reset all faults” command in the recommended diagnostic tool or equivalent can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications
Shop Talk:
Possible causes of this fault code include:
1. Stuck in-range exhaust gas pressure sensor reading.
2. High resistance in the exhaust gas pressure sensor signal or return lines.
3. Plugging or restriction in the exhaust gas pressure sensor tube.
4. Leaks in the exhaust system.
-
download MANCATS II v14.01 2014 Diagnostic software MAN CATS ( virtual machine )
MAN $75.00Rated 0 out of 5
Related products
-
Allison 1000 & 2000 Gen 4 Fault Codes: U0032 J1850 (Class 2) Serial Data Communication Link High
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1000 Class 2 Loss of Serial Data Communication
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U2104 CAN Bus Reset Counter Overrun
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0880 TCM Supply Voltage
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0876 Transmission Reverse Pressure Switch Circuit Stuck Open
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P1891 Engine Throttle Position Sensor Pulse Width Modulation (PWM) Signal Low Input
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0872 Transmission Pressure Switch Solenoid E Circuit Stuck Closed
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0871 Transmission Pressure Switch Solenoid E Circuit Stuck Open
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1096 J1850 (Class 2) IPC Controller State of Health Failure
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U0031 J1850 (Class 2) Serial Data Communication Link Low
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0122 Pedal Position Sensor Circuit Low Voltage
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0123 Pedal Position Sensor Circuit High Voltage
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1016 Class 2 J1850 (Class 2) Powertrain Controller State of Health Failure
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 P0719 Brake Switch ABS Input Low
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U0073 CAN Bus Reset Counter Overrun
1000 & 2000 Gen 4 $50.00Rated 0 out of 5
-
SERVICE MANUAL Eaton Fuller® HD FR/FRO TransmissionsTRSM2400April 2013
TRUCK MANUALSRated 0 out of 5