Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 7273 PID: SPN: 1209 FMI: 1/17 Exhaust Gas Pressure – Data Valid But Below Normal Operating Range – Least Severe Level
Lamp:
Amber
Reason:
The commanded VGT position and exhaust pressure were not met.
Effect:
None on performance.
Circuit Description:
The Engine Control Module (ECM) provides a 5 volt supply to the intake manifold pressure sensor on the sensor supply circuit. The ECM also provides a ground on the sensor return circuit. The intake manifold pressure sensor provides a signal to the ECM on the intake manifold pressure sensor signal circuit. This sensor signal voltage changes based on the pressure in the intake manifold. The exhaust gas pressure sensor is used to measure exhaust gas pressure in the exhaust manifold. This information is used by the Engine Control Module (ECM) to control emissions and Exhaust Gas Recirculation (EGR) valve operation. The ECM provides a 5 volt supply to the exhaust gas pressure sensor on the sensor supply circuit. The ECM also provides a ground on the sensor return circuit. The exhaust gas pressure sensor provides a signal to the ECM on the exhaust gas pressure sensor signal circuit. This sensor signal voltage changes, based on the pressure in the exhaust manifold.
Component Location:
1. The intake manifold 1 pressure/temperature sensor is located in the air intake manifold.
2. The exhaust gas pressure sensor is located above the front section of the exhaust manifold and is plumbed into the exhaust manifold.
Conditions for Running the Diagnostic:
This diagnostic runs when the engine is operating in SCR warm-up mode.
Conditions for Setting the Fault Codes:
The Engine Control Module (ECM) detected both the VGT position and the difference of the exhaust pressure and intake manifold pressure are lower than commanded.
Action Taken When the Fault Code is Active:
The ECM illuminates the amber check engine lamp and/or Malfunction Indicator Lamp (MIL) after the diagnostic fails on two consecutive trips.
Conditions for Clearing the Fault Code:
1. To validate the repair, start the engine and let it idle for up to 5 minutes.
2. The fault code status displayed by the recommended diagnostic tool or equivalent will change to inactive immediately after the diagnostic runs and passes.
3. The ECM will turn off the amber check engine lamp immediately after the diagnostic runs and passes.
4. For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.
5. The “reset all faults” command in the recommended diangostic tool or equivalent can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.
Shop Talk:
Possible causes of this fault code include:
1. A malfunctioning intake manifold pressure sensor.
2. A malfunctioning exhaust gas pressure sensor.
3. A malfunctioning turbocharger.
Related
-
JPRO 2022 v1 Commercial Vehicle Diagnostics V1 Software Download & Installation Service ( 1 PC )
JPRO $94.00Rated 0 out of 5
Related products
-
Allison 1000 & 2000 Gen 4 Fault Codes: P0876 Transmission Reverse Pressure Switch Circuit Stuck Open
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P2773 Torque Control Request Ignored – ECM/TCM
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U2105 CAN Bus ECM Error
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U0031 J1850 (Class 2) Serial Data Communication Link Low
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1041 J1850 (Class 2) ABS Controller State of Health Failure
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0122 Pedal Position Sensor Circuit Low Voltage
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0846 Transmission Pressure Switch Solenoid D Circuit Stuck Open
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P1892 Throttle Position Sensor Pulse Width Modulation (PWM) Signal High Input
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0123 Pedal Position Sensor Circuit High Voltage
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0847 Transmission Pressure Switch Solenoid D Circuit Stuck Closed
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0880 TCM Supply Voltage
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0875 Transmission Reverse Pressure Switch Circuit Malfunction
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P2771 Four-Wheel Drive Switch Circuit
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1064 J1850 (Class 2) TBC Controller State of Health Failure
1000 & 2000 Gen 4 $50.00Rated 0 out of 5