Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 516 PID: SID 232 SPN: 3514 FMI: 4 Sensor Supply 6 Circuit- Voltage Below Normal or Shorted to Low Source

Circuit Description
The sensor supply 6 circuit of the engine control module (ECM) is a dedicated (+) 5-VDC supply for the fuel rail pressure sensor.

Component Location
Sensor Supply 6 originates in the Engine Wiring Harness portion of the ECM. It supplies 5 volts to sensors in the engine wiring harness.

Conditions for Running the Diagnostics
This diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault Codes
The Engine Control Module (ECM) detected the sensor supply 6 signal voltage was less than 4.8-VDC for more than 1 second.

Action Taken When the Fault Code is Active
The ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.
Conditions for Clearing the Fault Code
To validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.
The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.
The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.
For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.
The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop Talk
Low voltage on the 5 volt supply line can be caused by a short circuit to ground in the supply line, a short circuit between the supply line and a return line, a failed sensor, or a damaged ECM power supply.

Possible Cause:
1) Fuel rail pressure sensor failure
2) Engine harness
3) ECM calibration