Cart $0.00
0
0
Subtotal: $0.00
No products in the cart.

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 4233 PID: SPN: 3515 FMI: 3 Aftertreatment 1 Diesel Exhaust Fluid Temperature 2 Sensor Circuit- Voltage Above Normal or Shorted to High Source

Circuit Description
The aftertreatment diesel exhaust fluid (DEF) sensor is a smart device that communicates to the ECM via the J1939 datalink. The aftertreatment DEF sensor performs its own internal diagnostics and reports malfunctions back to the primary engine control module via the J1939 datalink. The aftertreatment DEF sensor monitors the tank level, temperature and quality of the DEF fluid.

Component Location
The aftertreatment diesel exhaust fluid (DEF) sensor is located in the aftertreatment DEF tank. Location of the tank and sensor is OEM dependent. Refer to the OEM service manual.

Conditions for Running the Diagnostics
This diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault Codes
The Engine Control Module (ECM) detected the aftertreatment diesel exhaust fluid tank temperature signal voltage was out of range high.

Action Taken When the Fault Code is Active
The ECM illuminates the amber CHECK ENGINE lamp immediately when the diagnostic runs and fails.
Diesel exhaust fluid injection into the aftertreatment system is disabled.
Conditions for Clearing the Fault Code
To validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.
The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.
The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.
The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop Talk
Possible causes of this fault code include:

Malfunctioning DEF Quality Sensor

Possible Cause:
1) Aftertreatment DEF quality sensor failure
2) ECM calibration