Cummins ISX15 CM2250 (2010-12) Fault Code: 1925 PID: SID 334 SPN: 3482 FMI: 2 Aftertreatment Fuel Shutoff Valve 1- Data Erratic, Intermittent, or Incorrect
Circuit Description
This fault code checks for system errors in the aftertreatment fuel injection system. This diagnostic can detect malfunctions of the aftertreatment fuel shutoff valve.
Before active regeneration of the aftertreatment diesel particulate filter, a diagnostic test on the system is performed. The aftertreatment fuel injector opens and relieves fuel pressure in the line. The aftertreatment fuel pressure sensor must be reading atmospheric pressure at this point in the test. The aftertreatment fuel injector closes and the aftertreatment purge air actuator opens. This pressurizes the aftertreatment fuel system to vehicle air pressure. The diagnostic then checks to make sure the aftertreatment fuel pressure sensor is reading vehicle air pressure. The aftertreatment fuel shutoff valve then opens and allows pressurized fuel to enter the system. The aftertreatment fuel injector then opens and primes the system by purging the air from the line. The aftertreatment fuel shutoff valve and aftertreatment fuel injector then close and trap the fuel between the aftertreatment fuel shutoff valve and the aftertreatment fuel injector. The diagnostic checks to make sure the system maintains fuel pressure.
Component Location
The aftertreatment fuel injector is installed in the exhaust system in the turbocharger adapter pipe. The aftertreatment fuel pressure sensor and aftertreatment fuel shutoff valve are installed in the shutoff valve manifold. The aftertreatment purge air actuator is located above the shutoff valve manifold.
Conditions for Running the Diagnostics
This diagnostic runs during active regeneration of the aftertreatment diesel particulate filter.
Conditions for Setting the Fault Codes
The engine control module (ECM) detected an internally leaking aftertreatment fuel shutoff valve, aftertreatment purge air actuator, or a stuck closed aftertreatment fuel injector.
Action Taken When the Fault Code is Active
The ECM illuminates the amber CHECK ENGINE lamp and/or the malfunction indicator lamp (MIL) immediately when the diagnostic runs and fails.
Active regeneration of the aftertreatment diesel particulate filter will be disabled until the next key cycle.
Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.
Conditions for Clearing the Fault Code
To validate the repair, perform INSITE? electronic service tool Aftertreatment Diesel Particulate Filter Regeneration Test. Once the temperatures in the aftertreatment are warm enough to inject diesel fuel into the exhaust, the diagnostic will run.
The fault code status displayed by INSITE? electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.
The ECM will turn off the amber CHECK ENGINE lamp after the diagnostic runs and passes.
For On-Board Diagnostics (OBD) engines, the ECM will turn off the MIL after three consecutive trips where the diagnostic runs and passes.
The ?Reset All Faults? command in INSITE? electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications
Shop Talk
Possible causes of this fault code include:
Internal leak of the aftertreatment fuel shutoff valve allowing fuel pressure to leak past the shutoff valve.
Possible Cause:
1) Aftertreatment fuel Pressure Sensor failure
2) Aftertreatment Injector
3) ECM calibration
Related
-
PF Diagnose 2.0.2.23 Diagnostics Software 2013 – Full Heavy & Medium Duty with OBDII Support – Online Installation Service
PF Diagnose $60.00Rated 0 out of 5 -
CAT Engine Reprogramming Tool for flash programming C1.8, C2.4, C3.8 & C3.3B + Guide
CAT $50.00Rated 0 out of 5
Related products
-
Allison 1000 & 2000 Gen 4 Fault Codes: P0872 Transmission Pressure Switch Solenoid E Circuit Stuck Closed
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P1688 Unmanaged Engine Torque Delivered To TCM Signal
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1000 Class 2 Loss of Serial Data Communication
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P2773 Torque Control Request Ignored – ECM/TCM
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1041 J1850 (Class 2) ABS Controller State of Health Failure
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0880 TCM Supply Voltage
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P2810 Solenoid G Electrical
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1064 J1850 (Class 2) TBC Controller State of Health Failure
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0847 Transmission Pressure Switch Solenoid D Circuit Stuck Closed
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1016 Class 2 J1850 (Class 2) Powertrain Controller State of Health Failure
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1096 J1850 (Class 2) IPC Controller State of Health Failure
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1300 J1850 (Class 2) Serial Data Communication Link Low
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U2104 CAN Bus Reset Counter Overrun
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P2771 Four-Wheel Drive Switch Circuit
1000 & 2000 Gen 4 $50.00Rated 0 out of 5