Cummins ISX12 CM2250 (2010-12) Fault Code: 331 PID: SID 2 SPN: 652 FMI: 5 injector Solenoid Driver Cylinder 2 Circuit- Current Below Normal or Open Circuit
Circuit Description
The injector solenoid valves control fueling quantity and injection timing. The electronic control module (ECM) energizes the solenoid by closing a high-side and a low-side switch. Each injector circuit has a dedicated low-side switch that completes the circuit path to ground inside the ECM.
Component Location
The engine harness connects the ECM to the pass-through connector(s) that are located in the rocker housing. Internal injector harnesses are located under the valve cover and connect the injectors to the engine harness at the pass-through connector(s).
Conditions for Running the Diagnostics
This diagnostic runs continuously when the engine is operating.
Conditions for Setting the Fault Codes
The ECM senses current as each injector is actuated. If the ECM detects a persistent circuit error on an injector circuit, this fault code will become active. If a circuit error is determined to cause excessive current, the ECM will disable the injection event for the faulty cylinder(s).
Action Taken When the Fault Code is Active
The ECM illuminates the amber CHECK ENGINE light and/or the malfunction indicator lamp (MIL) immediately when the diagnostic runs and fails.
The injector will be disabled for the malfunctioning cylinder.
Conditions for Clearing the Fault Code
To validate the repair, start the engine and let it idle for 1 minute. The ECM will attempt to enable any disabled injector circuit when the engine is started and approximately once per minute while the engine is operating. If an injector circuit fault is active and the faulty condition is repaired, the fault will become inactive once the engine is restarted or if the engine is permitted to idle for more than a minute.
The fault code status displayed by INSITE? electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.
The ECM will turn off the amber CHECK ENGINE lamp after the diagnostic runs and passes.
For On-Board Diagnostic (OBD) engines, the ECM will turn off the MIL after three consecutive trips where the diagnostic runs and passes.
The ?Reset All Faults? command in INSITE? electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.
Shop Talk
If more than one injector fault code is occurring, and the faults occur for injector circuits in the same bank, a short circuit exists.
If a fault condition is intermittent, and especially if more than one injector fault code is occurring, look for a wire harness that can short to components inside the rocker housing or a short circuit to ground in the injector solenoid. When looking for short circuits in the injector harnesses, pay particular attention to the wire insulation, making sure there are no shorts to a rocker lever. An intermittent short can result if the wiring harness insulation rubs through near a rocker lever. An intermittent short can cause a single injector fault code.
If the fault(s) occur intermittently, the engine can exhibit a misfire even if the injector circuit fault code does not always register. If a single cylinder exhibits misfires, look for an open circuit problem. If several cylinders on the same bank exhibit misfires, look for a short circuit anywhere in the bank of cylinders.
Possible causes of a single injector fault include:
Open circuit in the engine harness(es) or injector solenoid
High resistance in a single injector or injector solenoid
Extremely low resistance in an injector solenoid (injector shorted internally but not to ground)
Malfunctioning or damaged ECM.
Possible causes of multiple injector fault codes in the same bank of injectors include:
Short circuit in the engine harness(es) – either shorts to ground or to other wires in the engine harness
Short circuit in any of the three injectors in the bank – shorts to ground
Malfunctioning or damaged ECM.
Same Bank Fault Codes:
Bank 1 – Front Bank: Fault Codes 322, 324, 331
Bank 2 – Rear Bank: Fault Codes 323, 325, 332.
Possible Cause:
1) Engine Harness
2) injector Harness
3) Injector 1,2,3 failure
4) ECM calibration
Related
-
International Truck ISIS – Oncommand Service Information Q4.2020 [04.2020]
Navistar $85.00Rated 0 out of 5
-
DPF EGR SCR BAC ERG Delete & Flash CAAT Cummings Detroit Dodge Mack Volvo Collection of DELETE files
CAT $200.00Rated 0 out of 5 -
download Hitachi Construction Machinery MPDr Ver 3.7.0.0 [10.2020] Diagnostic Software
Hitachi $76.00Rated 0 out of 5 -
Hino Diagnostic eXplorer 2 – Hino DX2 v1.1.21.4 with keygen unlocked ( Hino trucks )
Hino $60.00Rated 0 out of 5 -
Wabco ToolBox plus 13.7.0.1 + ECAS CAN2 v3.00 Diagnostics Software
Trucks software $84.00Rated 0 out of 5 -
download MANCATS II v14.01 2014 Diagnostic software MAN CATS ( virtual machine )
MAN $75.00Rated 0 out of 5 -
Detroit Diesel Diagnostic Link DDDL 8.0 PRO PROFESSIONAL Software trucks
Detroit $25.00Rated 0 out of 5
Related products
-
Allison 1000 & 2000 Gen 4 Fault Codes: P2773 Torque Control Request Ignored – ECM/TCM
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U2105 CAN Bus ECM Error
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0873 Transmission Pressure Switch Solenoid E Circuit High
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P1688 Unmanaged Engine Torque Delivered To TCM Signal
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1064 J1850 (Class 2) TBC Controller State of Health Failure
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P1779 Engine Torque Delivered To TCM Signal
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1016 Class 2 J1850 (Class 2) Powertrain Controller State of Health Failure
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0871 Transmission Pressure Switch Solenoid E Circuit Stuck Open
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0875 Transmission Reverse Pressure Switch Circuit Malfunction
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U0032 J1850 (Class 2) Serial Data Communication Link High
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P1892 Throttle Position Sensor Pulse Width Modulation (PWM) Signal High Input
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U0100 CAN Bus ECM Error
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0870 Transmission Pressure Switch Solenoid E Circuit
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U0073 CAN Bus Reset Counter Overrun
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0847 Transmission Pressure Switch Solenoid D Circuit Stuck Closed
1000 & 2000 Gen 4 $50.00Rated 0 out of 5
-
SERVICE MANUAL International Engines DT466 & DT530 (1995-1998)
INTERNATIONAL ENGINES $34.00Rated 0 out of 5