Cummins ISX11.9 CM2250 (2010-12) Fault Code: 3579 PID: SPN: 4376 FMI: 5 Aftertreatment Diesel exhaust Fluid Return Valve- Current Below Normal or Open Circuit

Circuit Description
The aftertreatment diesel exhaust fluid return valve is controlled by the aftertreatment diesel exhaust fluid controller. The return valve position determines where diesel exhaust fluid will flow as it exits the dosing unit. When the return valve is activated, the dosing system will purge and return the diesel exhaust fluid in the lines to the tank.

Component Location
The aftertreatment diesel exhaust fluid return valve is internal to the aftertreatment diesel exhaust fluid dosing unit and can not be serviced separately.

Conditions for Running the Diagnostics
This diagnostic runs continuously when the keyswitch is in the ON position.

Conditions for Setting the Fault Codes
The diesel exhaust fluid controller detects that the diesel exhaust fluid return valve circuit is open.

Action Taken When the Fault Code is Active
The ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.
Engine torque will be reduced if the engine is operated for an extended period of time with this fault active
Conditions for Clearing the Fault Code
To validate the repair, start the engine and let it idle for 1 minute.
The fault code status displayed byINSITE? electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.
The ECM will turn off the amber CHECK ENGINE lamp after the diagnostic runs and passes.
For On-Board Diagnotic (OBD) engines, the ECM will turn off the MIL after three consecutive trips where the diagnostic runs and passes.
The ?Reset All Faults? command in INSITE? electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop Talk
If this fault is active, the dosing system may not be able to purge, which means there will be diesel exhaust fluid left in the lines. Care must be taken when removing connections. Also, the lines could freeze and become damaged in cold weather if the system is not properly purged.

Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

For intermittent power supply and datalink communication issues with Aftertreatment Components, it is highly recommended that the OEM Power Distribution Center fuses and relays be thoroughly checked for loose, missing or intermittent connections.

Possible Cause:
1) Aftertreatment DEF controller harness failure
2) ECM calibration