Cummins ISX11.9 CM2250 (2010-12) Fault Code: 3543 (MR) PID: SID 115 SPN: 4094 FMI: 31 Nox Limits Exceeded Due to Insufficient Reagent Quality- Condition Exists
Circuit Description
The engine control module (ECM) monitors the mono-nitrogen oxides (NOx) concentration in the engine’s exhaust gases using an aftertreatment intake NOx sensor and aftertreatment outlet NOx sensor. By comparing these two values, the ECM is able to determine the conversion efficiency of the SCR catalyst and dosing system.
Component Location
The location of the diesel exhaust fluid tank is original equipment manufacturer (OEM) dependent. The selective catalytic reduction (SCR) catalyst and aftertreatment NOx sensors are located in the vehicle’s exhaust system.
Conditions for Running the Diagnostics
This diagnostic runs after the diesel exhaust fluid tank has been refilled. Specific engine and aftertreatment conditions must be met. NOx sensor data is gathered over varying engine speeds and loads. When enough data has been gathered, the diagnostic will run, make a pass/fail decision, and begin to gather data again.
Conditions for Setting the Fault Codes
The ECM detects that the NOx conversion across the SCR catalyst is lower than expected, and the diesel exhaust fluid tank has recently been refilled.
Action Taken When the Fault Code is Active
There are three levels of action taken by the ECM when this fault code is active:
Level 1: Action taken immediately after the diagnostic runs and fails.
The ECM illuminates the amber CHECK ENGINE light and/or the MIL.
Level 2: Action taken if the engine is operated for a limited period of time with the fault code active:
The ECM illuminates the amber CHECK ENGINE light and/or the MIL.
Engine torque will be reduced.
Level 3: Action taken after extended engine operation with the fault code active, after engine shutdown, or extended idle with fault code active.
The ECM illuminates the amber CHECK ENGINE light and/or the MIL.
The ECM illuminates the red CHECK ENGINE light and/or the MIL.
Engine torque will be severely reduced.
Vehicle speed will be limited to 8 km [5 mi] per hour.
Conditions for Clearing the Fault Code
After completing a stationary regeneration (as instructed in this fault code troubleshooting tree) and no additional faults become active, the repair has been validated. Note that this fault code will still be active
It is necessary to use the “Reset All Faults” command in INSITE? electronic service tool to clear this fault and extinguish the amber CHECK ENGINE lamp and/or malfunction indicator lamp (MIL).
Shop Talk
Troubleshoot all other active NOx sensor and SCR dosing system related fault codes before this fault.
The SCR control system is able to detect when anything other than pure diesel exhaust fluid (DEF) is in the diesel exhaust fluid tank.
Possible causes of this fault include:
Malfunctioning diesel exhaust fluid dosing system
Exhaust system leaks
Malfunctioning SCR catalyst
Degraded, diluted, or incorrect diesel exhaust fluid
Diesel exhaust fluid deposits in decomposition tube.
This fault code can be set as a result of multiple failure modes. All steps of the troubleshooting tree must be completed.
Possible Cause:
1) Aftertreatment NOx sensor failure
2) Aftertreatment DEF dosing unit filter failure
3) Aftertreatment SCR catalyst failure
4) ECM calibration
Related
-
Hino Diagnostic eXplorer 2 – Hino DX2 v1.1.21.4 with keygen unlocked ( Hino trucks )
Hino $60.00Rated 0 out of 5
Related products
-
Allison 1000 & 2000 Gen 4 Fault Codes: U1000 Class 2 Loss of Serial Data Communication
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0873 Transmission Pressure Switch Solenoid E Circuit High
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1064 J1850 (Class 2) TBC Controller State of Health Failure
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U0073 CAN Bus Reset Counter Overrun
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P1891 Engine Throttle Position Sensor Pulse Width Modulation (PWM) Signal Low Input
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1096 J1850 (Class 2) IPC Controller State of Health Failure
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0123 Pedal Position Sensor Circuit High Voltage
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P2810 Solenoid G Electrical
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1016 Class 2 J1850 (Class 2) Powertrain Controller State of Health Failure
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U0031 J1850 (Class 2) Serial Data Communication Link Low
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0847 Transmission Pressure Switch Solenoid D Circuit Stuck Closed
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0848 Transmission Pressure Switch Solenoid D Circuit High
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1041 J1850 (Class 2) ABS Controller State of Health Failure
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1300 J1850 (Class 2) Serial Data Communication Link Low
1000 & 2000 Gen 4 $50.00Rated 0 out of 5
-
SERVICE MANUAL International Engines DT466E & DT530E (1999 & Older)
INTERNATIONAL ENGINES $31.00Rated 0 out of 5 -
SERVICE MANUAL DETROIT DIESEL EPA 07, EPA 10, GHG 14 TROUBLESHOOTING
DETROIT $38.00Rated 0 out of 5