Cummins ISX11.9 CM2250 (2010-12) Fault Code: 3543 (HD) PID: SID 115 SPN: 4094 FMI: 31 Nox Limits Exceeded Due to Insufficient Reagent Quality- Condition Exists
Circuit Description
The engine control module (ECM) monitors the NOx concentration in the engine exhaust gases using an aftertreatment intake NOx sensor and aftertreatment outlet NOx sensor. By comparing these two values, the ECM is able to determine the conversion efficiency of the selective catalytic reduction (SCR) catalyst and dosing system.
Component Location
The location of the diesel exhaust fluid (DEF) tank is original equipment manufacturer (OEM) dependent. The SCR catalyst and aftertreatment NOx sensors are located in the vehicle’s exhaust system.
Conditions for Running the Diagnostics
This diagnostic runs after the DEF tank has been refilled. Specific engine and aftertreatment conditions must be met. NOx sensor data is gathered over varying engine speeds and loads. When enough data has been gathered, the diagnostic will run, make a pass/fail decision, and begin to gather data again.
Conditions for Setting the Fault Codes
The ECM detects that the NOx conversion across the SCR catalyst is lower than expected, and the DEF tank has recently been refilled.
Action Taken When the Fault Code is Active
There are three levels of action taken by the ECM when this fault code is active:
Level 1: Action taken immediately after the diagnostic runs and fails.
The ECM illuminates the amber CHECK ENGINE light and/or the malfunction indicator lamp (MIL).
Level 2: Action taken if the engine is operated for a limited period of time with the fault code active:
The ECM illuminates the amber CHECK ENGINE light and/or the MIL.
Engine torque will be reduced.
Level 3: Action taken after extended engine operation with the fault code active, after engine shutdown, or extended idle with fault code active.
The ECM illuminates the amber CHECK ENGINE light and/or the MIL.
The ECM illuminates the red CHECK ENGINE light and/or the MIL.
Engine torque will be severely reduced.
Vehicle speed will be limited to 8 km [5 mi] per hour.
Conditions for Clearing the Fault Code
When all the results of the Dynamic Engine System Analysis Test have passed, then repair has been validated.
Note: This fault code will still be active.
Shop Talk
Troubleshoot all other active NOx sensor and SCR dosing system related fault codes before this fault.
The SCR control system is able to detect when anything other than pure DEF is in the DEF tank.
Possible causes of this fault include:
Malfunctioning DEF dosing system
Exhaust system leaks
Malfunctioning SCR catalyst
Degraded, diluted, or incorrect DEF
DEF deposits in decomposition tube.
This fault code can be set as a result of multiple failure modes. All steps of the troubleshooting tree must be completed.
Possible Cause:
1) Aftertreatment DEF dosing unit filter failure
2) ECM calibration
Related
-
Eaton Service Ranger 4.9 Engineering 4.9 [05.2021] Engineering Level ( 1 PC )
Eaton $67.00Rated 0 out of 5
-
DAF Davie Runtime v5.6.1 Davie XDc ll [02.2019] + Expire Fix 302.00 Unlock ( Windows 7 )
DAF $70.00Rated 0 out of 5 -
VOLVO PREMIUM TECH TOOL PTT 2.7.30 Developer + Devtool + INSTALATION VIDEO!
Trucks software $60.00Rated 0 out of 5 -
ddct Detroit diesel calibration tool (DDCT) v4.5 English Include Calibrations & Metafiles
Detroit $30.00Rated 0 out of 5
Related products
-
Allison 1000 & 2000 Gen 4 Fault Codes: U2104 CAN Bus Reset Counter Overrun
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P2771 Four-Wheel Drive Switch Circuit
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0871 Transmission Pressure Switch Solenoid E Circuit Stuck Open
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P1688 Unmanaged Engine Torque Delivered To TCM Signal
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U2105 CAN Bus ECM Error
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0872 Transmission Pressure Switch Solenoid E Circuit Stuck Closed
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0846 Transmission Pressure Switch Solenoid D Circuit Stuck Open
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0880 TCM Supply Voltage
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0847 Transmission Pressure Switch Solenoid D Circuit Stuck Closed
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U0032 J1850 (Class 2) Serial Data Communication Link High
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P2773 Torque Control Request Ignored – ECM/TCM
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P1892 Throttle Position Sensor Pulse Width Modulation (PWM) Signal High Input
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U0073 CAN Bus Reset Counter Overrun
1000 & 2000 Gen 4 $50.00Rated 0 out of 5
-
MANUAL SERVICE Deutz Combine 5650 H, 5660 HTS5670 H / HTS5680 H, 5690 HTS
DEUTZ $38.00Rated 0 out of 5 -
SERVICE MANUAL DETROIT DIESEL DD15 , DD13 Service Workshop Repair Manual
DETROIT $25.00Rated 0 out of 5