Cummins ISX11.9 CM2250 (2010-12) Fault Code: 2347 PID: 404 SPN: 2629 FMI: 15 Turbocharger Compressor Outlet Temperature (Calculated)- Data Valid But Above Normal Operating Range- Least Severe Level
Circuit Description
The turbocharger compressor outlet air temperature is calculated by the ECM. Turbocharger compressor outlet air temperature is derived by the ECM, based on engine operating conditions such as turbocharger compressor intake air temperature, barometric pressure, turbocharger speed, engine speed, intake manifold air temperature, and intake manifold pressure.
Component Location
There is not a physical turbocharger compressor outlet temperature sensor in the system. The turbocharger compressor outlet air temperature is a calculation of temperature of the air after it is compressed by the turbocharger compressor, but before exhaust gas recirculation (EGR) is mixed into the system, and before it enters the charge-air cooler.
Conditions for Running the Diagnostics
This diagnostic runs continuously when the engine is operating.
Conditions for Setting the Fault Codes
The ECM detects that the calculated turbocharger compressor outlet temperature is greater than 238?C [460?F].
Action Taken When the Fault Code is Active
The ECM logs the fault code immediately when the temperature threshold is exceeded.
Fuel is limited in an attempt to decrease the calculated compressor outlet temperature.
Conditions for Clearing the Fault Code
To validate the repair using a Diagnostic Road Test, utilize a route that incorporates both stop-and-go city driving and steady state highway driving. It may be necessary to load the unit for certain diagnostics in the ECM to run.
To validate the repair using a Chassis Dynamometer Test, utilize a routine that incorporates acceleration and motoring events, steady state highway operation, and load. This will simulate normal driving and allow the diagnostics in the ECM to run.
The fault code status displayed by INSITE? electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.
The ?Reset All Faults? command in INSITE? electronic service tool can be used to clear active and inactive faults.
Shop Talk
Possible caused of this fault code include:
Air intake leaks allowing hot under-hood air to enter the intake system
Faulty intake manifold pressure readings
High turbocharger speed readings
Faulty barometric pressure readings
Stuck variable geometry turbocharger.
NOTE: Unless the issue is a malfunctioning barometric pressure sensor or intake manifold pressure sensor, this fault code will most likely not be active with no load in the shop. The engine will most likely need to be loaded to trip this fault code, and to determine if the malfunction has been found and repaired.
Possible Cause:
1) Barometric air pressure sensor failure
2) Intake manifold pressure sensor failure
3) ECM calibration
Related
-
DAF Davie Runtime v5.6.1 Davie XDc ll [02.2019] + Expire Fix 302.00 Unlock ( Windows 7 )
DAF $70.00Rated 0 out of 5 -
JOHN DEERE SERVICE ADVISOR 5.3.225 DATABASE AG + CF ENGLISH 2023
John Deere $250.00Rated 0 out of 5
Related products
-
Allison 1000 & 2000 Gen 4 Fault Codes: P2810 Solenoid G Electrical
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U0073 CAN Bus Reset Counter Overrun
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P2771 Four-Wheel Drive Switch Circuit
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0847 Transmission Pressure Switch Solenoid D Circuit Stuck Closed
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U2104 CAN Bus Reset Counter Overrun
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1301 J1850 (Class 2) Serial Data Communication Link Low
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0880 TCM Supply Voltage
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1016 Class 2 J1850 (Class 2) Powertrain Controller State of Health Failure
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0876 Transmission Reverse Pressure Switch Circuit Stuck Open
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1064 J1850 (Class 2) TBC Controller State of Health Failure
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0122 Pedal Position Sensor Circuit Low Voltage
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P1688 Unmanaged Engine Torque Delivered To TCM Signal
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P2773 Torque Control Request Ignored – ECM/TCM
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P1892 Throttle Position Sensor Pulse Width Modulation (PWM) Signal High Input
1000 & 2000 Gen 4 $50.00Rated 0 out of 5
-
MANUAL SERVICE Deutz Combine 5650 H, 5660 HTS5670 H / HTS5680 H, 5690 HTS
DEUTZ $38.00Rated 0 out of 5 -
SERVICE MANUAL International Engines MaxxForce 7 (2007-2009)
INTERNATIONAL ENGINES $31.00Rated 0 out of 5