Cummins ISX11.9 CM2250 (2010-12) Fault Code: 1361 PID: 372 SPN: 974 FMI: 4 Remote Accelerator Pedal or Lever Position Sensor 1 Circuit- Voltage Below Normal or Shorted to Low Source
Circuit Description
The remote accelerator position sensor is a potentiometer attached to the remote accelerator lever. The remote accelerator position sensor varies the signal voltage to the engine control module (ECM) as the remote accelerator lever is depressed and released. Low signal voltage is received by the ECM when the remote accelerator lever is at 0 percent. A high signal voltage is received by the ECM when the remote accelerator is at 100 percent. The remote accelerator pedal position circuit contains a remote accelerator pedal position 5 volt supply, remote accelerator pedal position return, and remote accelerator pedal position signal.
Component Location
The remote accelerator pedal or lever location varies with each original equipment manufacturer (OEM). Refer to the equipment manufacturer service information.
Conditions for Running the Diagnostics
This diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.
Conditions for Setting the Fault Codes
The ECM detected the remote accelerator pedal signal voltage less than 0.132-VDC for more than 20 seconds.
Action Taken When the Fault Code is Active
The ECM illuminates the amber CHECK ENGINE lamp immediately after the diagnostic runs and fails.
Conditions for Clearing the Fault Code
To validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.
The fault code status displayed by INSITE? electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.
The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.
The Reset All Faults command in INSITE? electronic service tool can be used to clear active and inactive faults, as well as extinguish the malfunction indicator lamp for on-board diagnostics applications.
Shop Talk
If troubleshooting an intermittent accelerator problem:
The remote accelerator pedal or lever position sensor signal voltage can be monitored with INSITE? electronic service tool, while flexing the harness to locate the intermittent connection. Intermittent connections will show up as abrupt changes in signal voltage displayed by INSITE? electronic service tool.
Possible causes of this fault code include:
Remote accelerator pedal or lever position signal shorted to engine ground or RETURN wires in the OEM harness or sensor
Damaged remote accelerator pedal or lever position sensor
Open circuit in the remote accelerator SIGNAL, SUPPLY, or RETRUN wire in the harness or connectors.
Note: The three wires in the remote accelerator position sensor circuit must be twisted together.
For intermittent power supply and datalink communication issues with aftertreatment components, it is highly recommended that the OEM Power Distribution Center fuses and relays be thoroughly checked for loose, missing, or intermittent connections.
Possible Cause:
1) OEM harness
2) ECM calibration
-
John Deere & Hitachi Parts ADVISOR 2020 [08.2020] Offline DVD Spare Parts Catalog
John Deere $120.00Rated 0 out of 5
-
10 IN 1 FOR CAT SIS Caterpillar 2021 Full Service Dealer INCLUDING CAT 2019 C
CAT $110.00Rated 0 out of 5 -
download Hitachi Construction Machinery MPDr Ver 3.7.0.0 [10.2020] Diagnostic Software
Hitachi $76.00Rated 0 out of 5 -
PF Diagnose 2.0.2.23 Diagnostics Software 2013 – Full Heavy & Medium Duty with OBDII Support – Online Installation Service
PF Diagnose $60.00Rated 0 out of 5 -
premium volvo tech tool update 2.8.150 diagnostic software 1pc
Trucks software $150.00Rated 0 out of 5 -
Hino Diagnostic eXplorer 2 – Hino DX2 1.1.19.1 with keygen unlocked ( Hino trucks )
Hino $50.00Rated 0 out of 5
Related products
-
Allison 1000 & 2000 Gen 4 Fault Codes: P0846 Transmission Pressure Switch Solenoid D Circuit Stuck Open
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0876 Transmission Reverse Pressure Switch Circuit Stuck Open
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P1891 Engine Throttle Position Sensor Pulse Width Modulation (PWM) Signal Low Input
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0847 Transmission Pressure Switch Solenoid D Circuit Stuck Closed
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0872 Transmission Pressure Switch Solenoid E Circuit Stuck Closed
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P1688 Unmanaged Engine Torque Delivered To TCM Signal
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0870 Transmission Pressure Switch Solenoid E Circuit
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P1892 Throttle Position Sensor Pulse Width Modulation (PWM) Signal High Input
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0880 TCM Supply Voltage
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1064 J1850 (Class 2) TBC Controller State of Health Failure
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1016 Class 2 J1850 (Class 2) Powertrain Controller State of Health Failure
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0875 Transmission Reverse Pressure Switch Circuit Malfunction
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0122 Pedal Position Sensor Circuit Low Voltage
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U2105 CAN Bus ECM Error
1000 & 2000 Gen 4 $50.00Rated 0 out of 5
-
SERVICE MANUAL DETROIT DIESEL DDEC III-IV Single ECM Troubleshooting Guide
DETROIT $48.00Rated 0 out of 5