Cummins ISL CM850 (2003-06) Fault Code: 195 (2 wires) PID: 111 SPN: 111 FMI: 3 Coolant Level Sensor 1 Circuit – Voltage Above Normal or Shorted to High Source. High signal voltage detected at engine coolant level circuit.
Cummins ISL CM850 (2003-06) Fault Code: 195 (2 wires) PID: 111 SPN: 111 FMI: 3 Coolant Level Sensor 1 Circuit – Voltage Above Normal or Shorted to High Source. High signal voltage detected at engine coolant level circuit.
Possible causes of this fault code include:
?Open return or signal circuit in the harness, connectors, or sensor
?Signal wire shorted to sensor supply or battery voltage.
Possible repairs:
1)Replace the engine coolant level sensor.
2)Repair or replace the OEM harness.
3)Replace the ECM.
-
download Hitachi Construction Machinery MPDr Ver 3.7.0.0 [10.2020] Diagnostic Software
Hitachi $76.00Rated 0 out of 5
-
CAT ET 2021A (Caterpillar Electronic Technician) + Factory Password (1 PC )
CAT $65.00Rated 0 out of 5 -
VOLVO PREMIUM TECH TOOL PTT 2.7.116 + APCI 2021 + devtool ( ONLINE )
Trucks software $80.00Rated 0 out of 5 -
DAF Davie Runtime v5.6.1 Davie XDc ll [02.2019] + Expire Fix 302.00 Unlock ( Windows 7 )
DAF $70.00Rated 0 out of 5 -
Bobcat Service Library [03.2019] Service, Operator, Maintenance, Bulletines, etc full update
Bobcat $110.00Rated 0 out of 5 -
Scania SDP3 2.48.6 Diagnosis & Programming for VCI 3 VCI3 without Dongle
Scania $30.00Rated 0 out of 5
Related products
-
SERVICE MANUAL International Engines MaxxForce DT 9 10 (2014 & Newer)
INTERNATIONAL ENGINES $17.00Rated 0 out of 5 -
SERVICE MANUAL Carrie Genesis R70 Genesis R90 Genesis TR1000 Multi -Temp
CARRIE $25.00Rated 0 out of 5 -
SERVICE MANUAL DETROIT DIESEL EPA 07, EPA 10, GHG 14 TROUBLESHOOTING
DETROIT $38.00Rated 0 out of 5 -
MANUAL SERVICE Deutz Combine 5650 H, 5660 HTS5670 H / HTS5680 H, 5690 HTS
DEUTZ $38.00Rated 0 out of 5