Cummins ISL CM850 (2003-06) Fault Code: 135 (Auto) PID: 100 SPN: 100 FMI: 3 Oil Pressure Sensor Circuit – Voltage Above Normal, or Shorted to High Source. High signal voltage detected at the engine oil pressure circuit.
Cummins ISL CM850 (2003-06) Fault Code: 135 (Auto) PID: 100 SPN: 100 FMI: 3 Oil Pressure Sensor Circuit – Voltage Above Normal, or Shorted to High Source. High signal voltage detected at the engine oil pressure circuit.
The oil pressure sensor shares supply and return wires in the engine harness with other sensors. Opens and shorts in the engine harness can cause multiple fault codes to be active. Before troubleshooting Fault Code 135, check for multiple faults.
Possible causes:
1)Open return circuit in the harness, connectors, or sensor
2)Signal circuit shorted to sensor supply or battery voltage.
Possible repairs:
1)Replace the oil pressure sensor.
2)Replace the ECM.
3)Replace the engine harness.
-
Volvo Premium Tech Tool PTT 2.8.130 Diagnostic Software 04.2022 ACPI ( 1 PC )
Trucks software $143.00Rated 0 out of 5 -
PF Diagnose 2.0.2.23 Diagnostics Software 2013 – Full Heavy & Medium Duty with OBDII Support – Online Installation Service
PF Diagnose $60.00Rated 0 out of 5 -
CAT CDVR PC Software – Caterpillar Digital Voltage Regulator (CDVR) WINDOWS 10
CAT $45.00Rated 0 out of 5
-
premium volvo tech tool update 2.8.150 diagnostic software 1pc
Trucks software $150.00Rated 0 out of 5 -
Volvo PROSIS Offline 2019 Parts Catalog Installation Service
Trucks software $45.00Rated 0 out of 5 -
Scania SDP3 2.48.6 Diagnosis & Programming for VCI 3 VCI3 without Dongle
Scania $30.00Rated 0 out of 5 -
CAT ET 2021A (Caterpillar Electronic Technician) + Factory Password (1 PC )
CAT $65.00Rated 0 out of 5
Related products
-
SERVICE MANUAL DETROIT DIESE LDDEC VI – CPC Vehicle Interface Harness Schematic
DETROIT $15.00Rated 0 out of 5