Cummins ISL CM850 (2003-06) Fault Code: 1241 PID: SPN: 2623 FMI: 4 Accelerator Pedal or Lever Position Sensor 2 Circuit – Voltage Below Normal or Shorted to Low Source. Low voltage detected at accelerator pedal position number 2 signal circuit.

Cummins ISL CM850 (2003-06) Fault Code: 1241 PID: SPN: 2623 FMI: 4 Accelerator Pedal or Lever Position Sensor 2 Circuit – Voltage Below Normal or Shorted to Low Source. Low voltage detected at accelerator pedal position number 2 signal circuit.

Newer engines use two throttle position sensors to determine the throttle position. Older throttle pedals used a single throttle position sensor and an idle validation switch. If Fault Codes 132 and 1241 are active when the accelerator pedal is in the idle position and Fault Code 132 goes inactive and Fault Code 1239 goes active when the throttle is depressed, the incorrect throttle pedal has been installed in the vehicle. A throttle pedal with two acceleration position sensors should be installed.

If troubleshooting an intermittent accelerator problem, the accelerator pedal position sensor 2 signal voltage can be monitored with the INSITE? electronic service tool, while flexing the harness to locate the intermittent connection.

Possible causes:

1)Accelerator pedal position signal shorted to engine ground or return wires in the OEM harness or sensor
2)Malfunctioning accelerator pedal position sensor
3)Open circuit in the accelerator signal, supply, or return wire in the harness or connectors.

Note: The three wires in the accelerator position sensor circuit must be twisted together.

Possible repairs:

1)Replace the accelerator pedal.
2)Repair or replace the OEM harness.
3) The removal and installation of the connector may correct the problem.
4)Replace the ECM.