Cummins ISB6.7 CM2350 (2013-17) Fault Code: 4233 PID: SPN: 3515 FMI: 3 Aftertreatment Diesel Exhaust Fluid Temperature Sensor – Voltage Above Normal or Shorted to High Source. High signal voltage or open circuit detected at the diesel exhaust fluid temperature sensor circuit
Cummins ISB6.7 CM2350 (2013-17) Fault Code: 4233 PID: SPN: 3515 FMI: 3 Aftertreatment Diesel Exhaust Fluid Temperature Sensor – Voltage Above Normal or Shorted to High Source. High signal voltage or open circuit detected at the diesel exhaust fluid temperature sensor circuit
Circuit Description
The aftertreatment diesel exhaust fluid (DEF) sensor is a smart device that communicates to the ECM via the J1939 datalink. The aftertreatment DEF sensor performs its own internal diagnostics and reports malfunctions back to the primary engine control module via the J1939 datalink. The aftertreatment DEF sensor monitors the tank level, temperature and quality of the DEF fluid.
Component Location
The aftertreatment diesel exhaust fluid (DEF) sensor is located in the aftertreatment DEF tank. Location of the tank and sensor is OEM dependent. Refer to the OEM service manual.
Conditions for Running the Diagnostics
This diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.
Conditions for Setting the Fault Codes
The Engine Control Module (ECM) detected the aftertreatment diesel exhaust fluid tank temperature signal voltage was out of range high.
Action Taken When the Fault Code is Active
1)The ECM illuminates the amber CHECK ENGINE lamp immediately when the diagnostic runs and fails.
2)Diesel exhaust fluid injection into the aftertreatment system is disabled.
Conditions for Clearing the Fault Code
1)To validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.
2)The fault code status displayed by INSITE? electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.
3)The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.
4)The Reset All Faults command in INSITE? electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.
Possible causes:
1)Malfunctioning DEF Quality Sensor
Related
-
Detroit Diesel Diagnostic Link DDDL 8.0 PRO PROFESSIONAL Software trucks
Detroit $25.00Rated 0 out of 5 -
Scania SDP3 2.48.6 Diagnosis & Programming for VCI 3 VCI3 without Dongle
Scania $30.00Rated 0 out of 5 -
Hino Diagnostic eXplorer 2 – Hino DX2 1.1.19.1 with keygen unlocked ( Hino trucks )
Hino $50.00Rated 0 out of 5 -
Hino Diagnostic eXplorer 2 – Hino DX2 v1.1.21.4 with keygen unlocked ( Hino trucks )
Hino $60.00Rated 0 out of 5