Cummins ISB6.7 CM2350 (2013-17) Fault Code: 3937 PID: SPN: 5848 FMI: 10 Aftertreatment 1 SCR Intermediate NH3 Sensor- Abnormal Rate of Change
Cummins ISB6.7 CM2350 (2013-17) Fault Code: 3937 PID: SPN: 5848 FMI: 10 Aftertreatment 1 SCR Intermediate NH3 Sensor- Abnormal Rate of Change
Circuit Description
The aftertreatment SCR intermediate NH3 (ammonia) sensor is a smart device that communicates with the engine control module via the J1939 data link. The aftertreatment intermediate NH3 sensor performs its own internal diagnostics and reports malfunctions back to the primary engine control module using the J1939 data link. The aftertreatment intermediate NH3 sensor is used to measure the ammonia in the aftertreatment system.
Component Location
The aftertreatment SCR intermediate NH3 sensor is located in the middle of the aftetreatment SCR catalyst.
Conditions for Running the Diagnostics
This diagnostic runs when the aftertreatment SCR intermediate temperature has been above 150 C [302 F] for a calibratible period of time while the engine is running.
Conditions for Setting the Fault Codes
The aftertreatment SCR intermediate NH3 Sensor reading was not valid.
Action Taken When the Fault Code is Active
The ECM illuminates the amber CHECK ENGINE lamp and/or Malfunction Indicator Lamp (MIL) after the diagnostic fails on two consecutive trips.
Conditions for Clearing the Fault Code
1)To validate the repair, start and operate the engine to raise exhaust temperatures. This can be done by either driving the vehicle or initiating a stationary regeneration using INSITE? electronic service tool.
2)The aftertreatment SCR intermediate temperature must be above 150 C [302 F] for 5 seconds before the aftertreatment SCR intermediate NH3 sensor can run its internal diagnostics
3)The fault code status displayed by INSITE? electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.
4)For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.
5)The Reset All Faults command in INSITE? electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.
Shop Talk
A malfunctioning aftertreatment SCR intermediate NH3 sensor probe
A malfunctioning aftertreatment SCR intermediate NH3 sensor module
Possible Causes:
1) ECM calibration
Related
-
volvo Devtool Studio V2 / V3 / V4 Developer tool plus 2.6 / 2.7
Trucks software $35.00Rated 0 out of 5 -
ddct Detroit diesel calibration tool (DDCT) v4.5 English Include Calibrations & Metafiles
Detroit $30.00Rated 0 out of 5
-
PF Diagnose 2.0.2.23 Diagnostics Software 2013 – Full Heavy & Medium Duty with OBDII Support – Online Installation Service
PF Diagnose $60.00Rated 0 out of 5 -
premium volvo tech tool update 2.8.150 diagnostic software 1pc
Trucks software $150.00Rated 0 out of 5 -
VOLVO PREMIUM TECH TOOL PTT 2.7.116 + APCI 2021 + devtool ( ONLINE )
Trucks software $80.00Rated 0 out of 5 -
DOWNLOAD NISSAN UD DIESEL PC-CONSULT DIAGNOSTIC 1.1.13 & PC-REPROMASTER 1.2.0
NISSAN UD $100.00Rated 0 out of 5 -
Navistar international OnCommand service information 2018 software trucks
Navistar $50.00Rated 0 out of 5
Related products
-
SERVICE MANUAL DETROIT DIESEL DDEC VI – Application And Installation Manual
DETROIT $20.00Rated 0 out of 5 -
MANUAL SERVICE Deutz Combine 5650 H, 5660 HTS5670 H / HTS5680 H, 5690 HTS
DEUTZ $38.00Rated 0 out of 5