Cummins ISB6.7 CM2350 (2013-17) Fault Code: 3933 PID: SPN: 5851 FMI: 18 Aftertreatment 1 SCR Intermediate NH3 Gas Sensor Power Supply- Data Valid but Below Normal Operating Range- Moderately Severe Level
Cummins ISB6.7 CM2350 (2013-17) Fault Code: 3933 PID: SPN: 5851 FMI: 18 Aftertreatment 1 SCR Intermediate NH3 Gas Sensor Power Supply- Data Valid but Below Normal Operating Range- Moderately Severe Level
Circuit Description
The aftertreatment SCR intermediate NH3 (ammonia) sensor is a smart device that communicates with the engine control module via the J1939 data link. The aftertreatment intermediate NH3 sensor performs its own internal diagnostics and reports malfunctions back to the primary engine control module using the J1939 data link. The aftertreatment intermediate NH3 sensor is used to measure the ammonia in the aftertreatment system.
Component Location
The aftertreatment SCR intermediate NH3 sensor is located in the middle of the aftetreatment SCR catalyst.
Conditions for Running the Diagnostics
This diagnostic runs when the aftertreatment SCR intermediate temperature has been above 150 C [302 F] for a calibratible period of time while the engine is running.
Conditions for Setting the Fault Codes
The aftertreatment SCR intermediate NH3 sensor reported the battery voltage supply was less than 10 VDC.
Action Taken When the Fault Code is Active
1)The ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.
2)Diesel exhaust fluid injection into the aftertreatment system is disabled.
3)Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.
Conditions for Clearing the Fault Code
1)To validate the repair, start and operate the engine to raise exhaust temperatures. This can be done by either driving the vehicle or initiating a stationary regeneration using INSITE? electronic service tool.
2)The aftertreatment SCR intermediate temperature must be above 150 C [302 F] for 5 seconds before the aftertreatment SCR intermediate NH3 sensor can run its internal diagnostics
3)The fault code status displayed by INSITE? electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.
4)The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.
5)For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.
6)The Reset All Faults command in INSITE? electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.
Possible causes:
1) Low battery voltage supply
2) Incorrect sensor for the application (12 VDC versus 24 VDC)
3) Incorrect Battery System Voltage setting in INSITE
-
Volvo Impact 2021 Trucks & Buses 06.2021 DVD 9116 Spare Parts Catalog
Trucks software $55.00Rated 0 out of 5 -
2021 VOLVO PREMIUM TECH TOOL PTT V2.8.21 VCADS+DEVELOPER TOOL+APCI 2021/09 ( 1 PC )
Trucks software $85.00Rated 0 out of 5
-
ddct Detroit diesel calibration tool (DDCT) v4.5 English Include Calibrations & Metafiles
Detroit $30.00Rated 0 out of 5 -
DAF Davie Runtime v5.6.1 Davie XDc ll [02.2019] + Expire Fix 302.00 Unlock ( Windows 7 )
DAF $70.00Rated 0 out of 5 -
Wabco ToolBox plus 13.7.0.1 + ECAS CAN2 v3.00 Diagnostics Software
Trucks software $84.00Rated 0 out of 5 -
premium volvo tech tool update 2.8.150 diagnostic software 1pc
Trucks software $150.00Rated 0 out of 5 -
PACCAR Electronic Service Analyst 5.4.3.0 SW files 27.03.2021 software trucks
PACCAR $60.00Rated 0 out of 5 -
CAT CDVR PC Software – Caterpillar Digital Voltage Regulator (CDVR) WINDOWS 10
CAT $45.00Rated 0 out of 5
Related products
-
SERVICE MANUAL International Engines DT466 & DT530 (2001-2003) C
INTERNATIONAL ENGINES $31.00Rated 0 out of 5