Cummins ISB6.7 CM2350 (2013-17) Fault Code: 3911 PID: SPN: 5848 FMI: 9 Aftertreatment 1 SCR Intermediate NH3 Sensor- Abnormal Update Rate
Cummins ISB6.7 CM2350 (2013-17) Fault Code: 3911 PID: SPN: 5848 FMI: 9 Aftertreatment 1 SCR Intermediate NH3 Sensor- Abnormal Update Rate
Circuit Description
The aftertreatment SCR intermediate NH3 (ammonia) sensor is a smart device that communicates with the engine control module via the J1939 data link. The aftertreatment intermediate NH3 sensor performs its own internal diagnostics and reports malfunctions back to the primary engine control module using the J1939 data link. The aftertreatment intermediate NH3 sensor is used to measure the ammonia in the aftertreatment system.
Component Location
The aftertreatment SCR intermediate NH3 sensor is located in the middle of the aftetreatment SCR catalyst.
Conditions for Running the Diagnostics
This diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.
Conditions for Setting the Fault Codes
The Engine Control Module (ECM) detected a loss of communication with the aftertreatment SCR intermediate NH3 sensor.
Action Taken When the Fault Code is Active
1)The ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.
2)Diesel exhaust fluid injection into the aftertreatment system is disabled.
3)Engine torque will be severely reduced.
4)Vehicle speed will be limited to 8 km [5 mi] per hour after extended engine operation with the fault code active.
Conditions for Clearing the Fault Code
1)To validate the repair, start and operate the engine to raise exhaust temperatures. This can be done by either driving the vehicle or initiating a stationary regeneration using INSITE? electronic service tool.
2)The aftertreatment SCR intermediate temperature must be above 150 C [302 F] for 5 seconds before the aftertreatment SCR intermediate NH3 sensor can run its internal diagnostics
3)The fault code status displayed by INSITE? electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.
4)The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.
5)For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.
6)The Reset All Faults command in INSITE? electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.
Possible causes:
1) Low battery voltage supply to the aftertreatment SCR intermediate NH3 sensor
2) Incorrect terminating resistance of the SAE J1939 datalink circuit
3) A malfunctioning SAE J1939 datalink circuit
4) Intermittent communication from the aftertreatment SCR intermediate NH3 sensor
-
2021 VOLVO PREMIUM TECH TOOL PTT V2.8.21 VCADS+DEVELOPER TOOL+APCI 2021/09 ( 1 PC )
Trucks software $85.00Rated 0 out of 5 -
Volvo Premium Tech Tool PTT 2.8.130 Diagnostic Software 04.2022 ACPI ( 1 PC )
Trucks software $143.00Rated 0 out of 5 -
CAT Engine Reprogramming Tool for flash programming C1.8, C2.4, C3.8 & C3.3B + Guide
CAT $50.00Rated 0 out of 5
-
VOLVO PREMIUM TECH TOOL PTT 2.7.116 + APCI 2021 + devtool ( ONLINE )
Trucks software $80.00Rated 0 out of 5 -
CLAAS WebTIC Offline [11.2021] Service Information – ENGLISH Language
CLAAS $100.00Rated 0 out of 5 -
DAF Davie Runtime v5.6.1 Davie XDc ll [02.2019] + Expire Fix 302.00 Unlock ( Windows 7 )
DAF $70.00Rated 0 out of 5 -
Scania SDP3 2.48.6 Diagnosis & Programming for VCI 3 VCI3 without Dongle
Scania $30.00Rated 0 out of 5