Cummins ISB6.7 CM2350 (2013-17) Fault Code: 2556 PID: SID 70 SPN: 729 FMI: 4 Engine Intake Air Heater 1 Circuit- Voltage Below Normal or Shorted to Low Source
Cummins ISB6.7 CM2350 (2013-17) Fault Code: 2556 PID: SID 70 SPN: 729 FMI: 4 Engine Intake Air Heater 1 Circuit- Voltage Below Normal or Shorted to Low Source
Circuit Description
The intake air heater improves starting and white smoke control in cold ambient conditions.
The engine control module (ECM) controls relays that switch power to the intake air heater. Air heaters on 12 volt systems will have two relays while 24 volt systems only require one relay.
Component Location
The intake air heater is located at the air inlet connection to the intake manifold. The location of the intake air heater relays will vary by vehicle and engine configuration.
Conditions for Running the Diagnostics
This diagnostic runs when the keyswitch is in the ON position and when the pulse width modulated (PWM) device is getting energized or de-energized. In some cases, the diagnostics can also run at some fixed intervals.
Conditions for Setting the Fault Codes
The intake air heater circuit pulse width modulated (PWM) signal was not detected to be system voltage when the PWM signal was on.
Action Taken When the Fault Code is Active
1)The ECM illuminates the amber CHECK ENGINE lamp immediately when the diagnostic runs and fails.
2)The intake air heater operation will be disabled.
Conditions for Clearing the Fault Code
1)To validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.
2)The fault code status displayed by INSITE? electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.
3)The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.
4)For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.
5)The Reset All Faults command in INSITE? electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.
Possible causes:
1) A shorted intake air heater relay
2) Intake air heater relay supply wire shorted to ground.
-
JOHN DEERE SERVICE ADVISOR 5.3.225 DATABASE AG + CF ENGLISH 2023
John Deere $250.00Rated 0 out of 5
-
PACCAR Electronic Service Analyst 5.4.3.0 SW files 27.03.2021 software trucks
PACCAR $60.00Rated 0 out of 5 -
Detroit Diesel Diagnostic Link DDDL 8.0 PRO PROFESSIONAL Software trucks
Detroit $25.00Rated 0 out of 5 -
CAT CDVR PC Software – Caterpillar Digital Voltage Regulator (CDVR) WINDOWS 10
CAT $45.00Rated 0 out of 5 -
10 IN 1 FOR CAT SIS Caterpillar 2021 Full Service Dealer INCLUDING CAT 2019 C
CAT $110.00Rated 0 out of 5