Cummins ISB6.7 CM2350 (2013-17) Fault Code: 1677-Hardwired PID: SPN: 3031 FMI: 4 Aftertreatment 1 Diesel Exhaust Fluid Tank Temperature Sensor- Voltage Below Normal or Shorted to Low Source
Cummins ISB6.7 CM2350 (2013-17) Fault Code: 1677-Hardwired PID: SPN: 3031 FMI: 4 Aftertreatment 1 Diesel Exhaust Fluid Tank Temperature Sensor- Voltage Below Normal or Shorted to Low Source
Circuit Description
The aftertreatment diesel exhaust fluid tank temperature sensor is used to monitor the temperature of the aftertreatment diesel exhaust fluid inside the aftertreatment diesel exhaust fluid tank.
Component Location
The aftertreatment diesel exhaust fluid tank temperature sensor is located in the diesel exhaust fluid tank. Location of the tank and temperature sensor is OEM dependent. Refer to the OEM service manual.
Conditions for Running the Diagnostics
This diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.
Conditions for Setting the Fault Codes
The Engine Control Module (ECM) detected the aftertreatment diesel exhaust fluid tank temperature signal voltage was out of range low.
Action Taken When the Fault Code is Active
1)The ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.
2)Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.
Conditions for Clearing the Fault Code
1)To validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.
2)The fault code status displayed by INSITE? electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.
3)The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.
4)For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.
5)The Reset All Faults command in INSITE? electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.
Possible causes:
1) A malfunctioning aftertreatment diesel exhaust fluid tank temperature sensor
2) Signal shorted to ground in the harness
3) Signal shorted to return or ground in the sensor.
The type of diesel exhaust fluid tank temperature and level sensor used can vary depending on the vehicle OEM. As a result, the physical and/or electrical sensor configuration may vary slightly from what is shown in the troubleshooting and wiring diagram information.
Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.
For intermittent power supply and datalink communication issues with Aftertreatment Components, it is highly recommended that the OEM Power Distribution Center fuses and relays be thoroughly checked for loose, missing or intermittent connections.
Related
-
10 IN 1 FOR CAT SIS Caterpillar 2021 Full Service Dealer INCLUDING CAT 2019 C
CAT $110.00Rated 0 out of 5
-
JPRO 2022 v1 Commercial Vehicle Diagnostics V1 Software Download & Installation Service ( 1 PC )
JPRO $94.00Rated 0 out of 5 -
DOWNLOAD Paccar ESA Electronic Service Analyst 5.5.0 Diagnostic Software 2023
PACCAR $96.00Rated 0 out of 5 -
VOLVO PREMIUM TECH TOOL PTT 2.7.30 Developer + Devtool + INSTALATION VIDEO!
Trucks software $60.00Rated 0 out of 5 -
Navistar international OnCommand service information 2018 software trucks
Navistar $50.00Rated 0 out of 5
Related products
-
SERVICE MANUAL International Engines DT466 & DT530 (1999-2000) B
INTERNATIONAL ENGINES $29.00Rated 0 out of 5