Cummins ISB6.7 CM2350 (2013-17) Fault Code: 1117 PID: SID 251 SPN: 627 FMI: 2 Power Supply Lost With Ignition On- Data Erratic, Intermittent, or Incorrect
Cummins ISB6.7 CM2350 (2013-17) Fault Code: 1117 PID: SID 251 SPN: 627 FMI: 2 Power Supply Lost With Ignition On- Data Erratic, Intermittent, or Incorrect
Circuit Description
The engine control module (ECM) receives constant voltage from the batteries through the unswitched battery wires that are connected directly to the positive (+) battery post. The ECM receives switched battery input through the vehicle keyswitch wire when the vehicle keyswitch is turned ON.
Component Location
The ECM is connected to the battery by the OEM harness. This direct link provides a constant power supply for the ECM. The location of the battery will vary with the original equipment manufacturer (OEM). Refer to the OEM service manual.
Conditions for Running the Diagnostics
This diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.
Conditions for Setting the Fault Codes
The Engine Control Module (ECM) detected the primary ECM power supply dropped below a calibratible value while the keyswitch was in the ON position. The fault code will be active when the keyswitch is turned ON following the incomplete power-down event.
Action Taken When the Fault Code is Active
1)The ECM logs the fault code immediately when the diagnostic runs and fails.
2)Power-down data like trip information, maintenance monitor, and fault information will not get saved to 3)permanent memory when the keyswitch is turned OFF.
Conditions for Clearing the Fault Code
1)To validate the repair, start the engine, let it idle for 1 minute, and then shutdown the engine.
2)The fault code status displayed by INSITE? electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.
3)The Reset All Faults command in INSITE? electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.
Shop Talk
Make sure the ECM unswitched battery supply is coming directly from the battery and not the starter. If unswitched power is coming from the starter, it is possible for the battery voltage to drop low enough during cranking to set this fault active.This fault can also be caused by resistance in the ECM battery supply (+) or (-) circuits. Resistance in these circuits can cause the voltage level at the ECM input to drop low enough to set Fault Code 1117 active. Use of battery disconnect switches to turn off the engine or any device that disconnects battery voltage to the ECM within 10 seconds of turning the keyswitch OFF can cause damage to the aftertreatment system. The vehicle should not be operated with an active Fault Code 1117.
Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.
Possible Causes:
1) Loose Connections/ Terminals
2) Battery failure
3) OEM power harness
4) ECM power harness
5) OEM harness
6) ECM calibration
Related
-
John Deere & Hitachi Parts ADVISOR 2020 [08.2020] Offline DVD Spare Parts Catalog
John Deere $120.00Rated 0 out of 5 -
JOHN DEERE SERVICE ADVISOR 5.3.225 DATABASE AG + CF ENGLISH 2023
John Deere $250.00Rated 0 out of 5 -
DETROIT DDDL 8.14 SP3 – Detroit Diesel Diagnostic Link 8.14 SP3 2021 ( 1PC )
Detroit $73.00Rated 0 out of 5
Related products
-
SERVICE MANUAL International Engines VT275 (2004 & Older)
INTERNATIONAL ENGINES $21.00Rated 0 out of 5 -
SERVICE MANUAL Carrie Supra 422, 522,622, 722, 822,922, 644,744,844, 944 & Supra Multi-Temp
CARRIE $20.00Rated 0 out of 5 -
SERVICE MANUAL DETROIT DIESEL DD15 , DD13 Service Workshop Repair Manual
DETROIT $25.00Rated 0 out of 5